NX-200
112
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
7. High RSSI
at
–80dBm
adjust
*8
[Analog
Narrow]
1) Adj item: [An
HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AnL
HRSSI]
→
[AnL’
HRSSI]
→
[AnC
HRSSI]
→
[AnH’
HRSSI]
→
[AnH
HRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Analog Nar-
row)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
SSG
Panel
ANT
Universal
connector
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Analog
Wide]
1) Adj item: [Aw
HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AwL
HRSSI]
→
[AwL’
HRSSI]
→
[AwC
HRSSI]
→
[AwH’
HRSSI]
→
[AwH
HRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [High
RSSI (Analog Wide)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±3kHz)
[NXDN
Very
Narrow]
1) Adj item: [Nv
HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[NvL
HRSSI]
→
[NvL’
HRSSI]
→
[NvC
HRSSI]
→
[NvH’
HRSSI]
→
[NvH
HRSSI]
Adjust:
[
✳✳✳
]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (NXDN Very
Narrow)]
2) Adj item: [Low],
[Low’],
[Center],
[High’],
[High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
Adjust with the ana-
log signal.
*8: Because High RSSI at –80dBm (NXDN Narrow) is adjusted by adjusting High RSSI at –80dBm (Analog Narrow), it is not necessary to adjust