6
CV x PORTAMENTO RATE (or TIME)
(0 to 127, default: 98)
- sets the speed at which portamento glides between notes. Note that 0 is fastest rate but does not
mean portamento off, use portamento controller (below) for that! This value can also be varied in real
time using MIDI controller number 5 (portamento time). If this parameter is in view on the display, its
new value will not be displayed when varied using controller 5. However If varied via SYSEX, the new
value will be displayed.
CV x PORTAMENTO CONTROLLER
(Auto ,ON, OFF, 0-119, default: 65)
- sets the controller responsible for enabling-disabling the portamento control. If on or off are selected
these force on or off. If Auto is selected, then portamento is obtained only when you play in a legato
manner (i.e. playing the new note before releasing the old one), thus you can turn portamento on or
off, depending on how you play the notes.
CV x LFO DEPTH CONTROL
(pb, vel, aft, controllers 0-119, default: #1 mod
wheel).
- assigns which MIDI controller will control the LFO depth of modulation of the CV output.
CV x LFO DEPTH AMOUNT
(for controller maximum 0-127, default:65).
- allows you to set the maximum LFO depth for the CV out
CV x LFO ASSIGN Use LFO number
(1 to 2, default: A=1, B=2)
- lets you assign which of the two inbuilt LFOs will modulate the CV outputs.
CV x Gate Select
(default: 5v pull-up)
- you can select the following type outputs for the Gate output;
S-trig no pull-up
This would probably be used for Moogs & Korgs.
S-trig 5v pull-up
S-trig 15v pull-up
This would probably be used on the Yamaha CS range of synths instead of the Gate output.
Gate V-Trig 5v pull-up
Gate V-Trig 15v pull-up
These are the standard gates and should be used to run most synths including Roland,Arp, SCI.
CV x Fine Tune
( -127 to +127 default 0)
-
Fine tunes the mono-synth.
CV x Scale
( -127 to +127 default 0)
- This is used to tune in the octave scaling of your analogue synth. Will only need adjusting if your synth
sounds out of tune as you play further up the keyboard (see `Tuning in Your Analogue Synth`). - Check
whether CV select has been set correctly (see below).
CV x CV/HZ Select
( Volt/Oct or Hz/V or 1.2V/Oct
–
default: Volt/Oct scaling)
-
This is used to select the scaling system. Most synths will use Volt/Octave scaling, although most Korg
and Yamaha synths will require the Hz/V selection (note that the Korg Monopoly is Volt/Octave). For
the very few synths that employ 1.2V/Octave scaling (one tenth of a volt per semitone) the
1.2V/Octave mode should be selected.