X8 MIG WELDER
2.4 Operation
4. Upslope
The selected start and stop logics.
5. Estimated welding current
6. Estimated plate material thickness
7. Wire feed speed
8. Serial number of the power source, wire feeder's number (1 or 2) and user name
9. Welding process
10. Hot start
The selected start and stop logics.
11. Crater fill
The selected start and stop logics.
12. Voltage
13. Voltage/Fine tuning
Adjust the welding power with the left control knob.
Fine tune the secondary welding parameter with the right control knob. The adjustable secondary parameter
varies according to the welding process and function.
The welding power graph shows with grey raster pattern the area, where the selected values result in
globular transfer.
Figure 12: Raster pattern in the wire feed arc
In DPulse, WP Switch and DProcess, you can adjust two value sets: the first level and the second power level.
Press the left green button to toggle between them. Adjust the values with the control knobs. The other
power level is shown with gray line on the wire feed speed diagram.