X8 MIG WELDER
2.4 Operation
1. Memory channel
2. Welding power
The unit of the parameter varies according to the welding process.
3. Voltage
Note:
Not all processes have this parameter.
4. Fine tuning
The unit of the parameter varies according to the welding process.
5. Applied settings displayed in symbols
For more information on symbols, see
Kemppi symbols
.
Adjust the welding power with the left control knob.
Note:
The welding parameter shown is
Wire feed speed
,
Current
or
Plate Thickness
.
Fine tune the secondary welding parameter with the right control knob. The adjustable secondary parameter
varies according to the welding process and function.
Memory Channels view
Welding parameters are stored in the memory channels. The memory channel displays the same information
of the welding parameters as the
Welding
view. Each user has their own memory channels.
Press the
Channel
button on the left to see the
Channel
view. A menu of the memory channels appears on
the left side of the display. To take a channel into use, move focus to it with the right control knob. A tilted
number of the memory channel indicates that the parameters of the original memory channel have been
modified.
To save a modified channel, press and hold the
Channel
button or press
Save
on the green button of the
right knob.
Settings view
For more information on wire feeder's settings, see
Wire feeder settings view
on page 97.
Wire feeder settings view
You can adjust the selected memory channel or the settings of the wire feeder through the
Settings
view.
Press the
Settings
button to access the wire feeder settings. When the settings view is open, the
Settings
button lights up orange.
Modify the parameters with the right knob. Press the green button in the center of the knob to select and
turn the right knob to adjust a parameter.
Table 4: Wire feeder settings
Trigger
Change the welding gun trigger mode (2T/4T).
OPERATING MANUAL | EN
97
©
KEMPPI | 2018-09-28