X8 MIG WELDER
2.4 Operation
DPulse is a pulse welding process with two separate power levels. The welding power varies between these
two levels, and the parameters of each level are controlled independently. In the
Welding
view, toggle
between level 1 and level 2 by pressing the left Control Pad button. The inactive power level is shown with a
gray line on the wire feed speed diagram.
Figure 32: DPulse Welding view
To adjust the welding power / wire feed speed while welding, in the Control Pad's
Welding
view, turn the left
knob.
To fine tune voltage while welding, in the Control Pad's
Welding
view, turn the right knob.
When using DPulse, you can adjust the following parameters through
Settings
>
Parameters
:
• Wire Feed Speed: adjusts the wire feed speed for level 1.
• min: adjusts the minimum set value for wire feed speed
• max: adjusts the maximum set value for wire feed speed
• Fine tuning: adjusts the voltage (arc length).
• Dynamics: Adjusts the short circuit behavior. On the minus side, the arc is softer (less spatter). On the plus
side, the arc is harder (the arc is more stable).
• Pulse current %: -10...+15. Adjusts the pulse peak current. Use for controlling the droplet detachment.
• StartPower: -30...+30. Adjusts the power level for arc ignition.
• StartLevel: -30...+30. Fine tunes the arc length for arc ignition.
• StopPower: -30...+30. Adjusts the power level for arc stop.
You can adjust the following parameters through
Settings
>
DPulse
:
OPERATING MANUAL | EN
123
©
KEMPPI | 2018-09-28