X8 MIG WELDER
2.4 Operation
3.
Adjust the welding parameters.
4.
Weld for at least 4 welds of 5 seconds.
With several welds, the measurement result is more accurate.
The welder calibrates to the length of the interconnection cable. The values are saved, so you only need
to calibrate once after installing the welder package.
5.
After the calibration, you can view arc voltage on Control Pad and the wire feeder control panel during
and after welding. To view the arc voltage on Control Pad display, select
Voltage display mode
.
Arc
voltage
is the default setting.
Note:
It is recommendable to keep the voltage sensing cable connected at all times. However, if the
cable is not connected, the power source calculates the arc voltage according to the calibrating
values.
Note:
Repeat steps 1-4 every time you change the length of the interconnection or earth return cable.
2.4.2.3 Connecting to Kemppi cloud services
To use the Kemppi cloud services, connect the welding machine to the Internet either through a WLAN or a
wired connection. Form the connection by using the
Cloud services
view in the
View
menu. You can also see
the status of the Cloud services there.
Note:
Cloud communication requires that your network firewall allows outbound data through ports 80
(HTTP), 123 (NTP), 443 (HTTPS) and 8883 (Secure MQTT).
Kemppi cloud services include, for example, My Fleet and WeldEye.
For more information on My Fleet, see
My Fleet
. For more information on WeldEye, see
Introduction to
WeldEye for welding procedure and qualification management
on page 9 . For more information on
operating Control Pad, see
Control Pad
on page 84.
WLAN connection
Proceed as follows:
1.
Go to the
View
menu >
Cloud services
>
WiFi settings
.
OPERATING MANUAL | EN
106
©