www.kelichina.com
Page 33 of 38
Turn the indicator off, plug in the address modifying plug, and connect the sensor to
the indicator (they can only be tested one by one). Power on, the code of the sensor
will be displayed after self examination. Press ENTER, the load value will be shown
according which we can indicate whether the sensor is ok or not (find detailed
information in section 7).
7.
How to judge the breakdown of an indicator.
Connect a spare sensor to the indicator, plug the calibration head in, and press
CALIBRATE while self-examining. Set the number of sensors to be ‘1’, if it works
normal after exiting, that is to say the indicator is ok otherwise it is broken.
8.
Malfunction description: Constant displaying of disordered data.
Possible reason: the interfaces of indicator and screen do not match.
Solution: find the connection indication in the manual, and make the connection
according to that.
9.
Malfunction description: it shows ‘…………….’ after self-examining.
Possible reason: wrong connection of the green wire and white wire in junction box.
Solution: cut off the electricity. Check the connection between cables to bus through
an indicator, red-red, black-black, white-white, green-green, make sure that there is no
short circuit.
10.
Malfunction description: no display in weighing software after connecting an indicator
to a PC.
Possible reason: the connection between them is incorrect or bound rate does not
match each other.
Solution: find the connection indication between them in the manual; check the
connection and bound rate.
11.
Malfunction description: disordered data displayed in weighing software after
connecting an indicator to a PC.
Possible reason: Bound rate does not match each other.
Solution: Set the bound rate in the indicator and weighing software.
12.
Malfunction description: A big and stable number is shown in the indicator still after
the tested vehicle moves out.
Possible reason: the limit position is blocked.
Solution: check the limit position, and fix it to the right place.
13.
Malfunction description: Err message is shown after booting. The indicator tests each
sensor under address modifying status and all the sensors are proved to work well.
Connect sensors one by one from NO. 1, and the indicator shows err message without
having all of them connected.
Possible reason: the power of this indicator is limited.
Solution: replace it with a more powerful one