Steps
Operation
Display
Note
1
.
Power on and
choose
operating mode
Press[Auto
Corner-Rectify]
Enter
[1][1][1][1][1][1]
,
Press[Enter]
[-------]
[111111]
[Ant 04]
Note to enter password
Only if the password is 111111 can you
carry on the next step, otherwise return to
the weighing states.
Default load cells number is 4;
2.Set
Corner-Rectify
number
Press[0][6]
Press[Enter]
[Ant 06]
Enter number, 6 for example
Press[Enter] continue to next step
3. Set pressing
weight value
Press
[0][0][5][0][0][0]
Press[Enter]
[ 000000]
[005000]
Display the pressing weight 0
Enter Pressing weight
,
5000kg for
example
Press [Enter] continue to next step
4. Confirm the first
corner
Press[Enter]
[No 1]
Display the first corner, after loading and
being stable. 5000kg for example
Press[Enter] to confirm
,
and continue to
next step
5. Confirm the
second corner
Press[Enter]
[No 2]
Display the second corner, after loading
and being stable. 5000kg for example
Press[Enter] to confirm
,
and continue to
next step
7. Confirm number
n corner
Press[Enter]
[No n]
[ …… ]
[ End ]
N is total corner number, after loading and
being stable. 5000kg for example
Press[Enter], wait for about 30 seconds
,
End the Corner-Rectify. Press [Enter] or
power off to quit.
Repeat calibration
▲
!
Error caused by power intermit, please press [check] or shut down
power and reset.
!
After Auto Corner-Rectify, demarcation must be applied again