www.kelichina.com
Page 23 of 38
13. Check
scale dead load
span
[Enter]
[Enter]
[noLoAd]
[000000]
[------]
Check scale dead load span. Press [Enter]
after the scale is unloaded and stable
Displays the ISN value under unload state,
which should close to zero.
Press [Check] to skip this step, press [Weight]
back to the weighing state
Press [Enter] and wait for 1~2 seconds
,
enter
the next step automatically.
Press [Check] to skip this step, press [Weight]
back to the weighing state
14 Load the
calibrated
weight value
[Enter]
[Enter]
Press[0]
、
[1]
、
[0]
、
[0]
、
[0]
、
[0]
[Enter]
[AlloAd]
[******]
[000000]
[010000]
[------]
Load the calibrated weight value, the closer to
the full capacity the better, for example
10000Kg. Press [Enter] after the scale is
stable.
Press [Check] to skip this step, press [Weight]
back to the weighing state
Display the ISN value of the digital load cell
after being loaded. As the digital load cells
are calibrated before releasing from factory,
normally the value should close to the
loading weight value.
Display the set calibration weight value state.
Set calibrated weight value to 10000Kg
Waiting for 1-2 seconds, quite calibration
state and back to the weighing state
automatically. Then the calibration has
finished.
▲
!
Pull out the calibration plug after operation.
▲
!
Error caused by power intermit, please press [check] or shut down power
and reset.
。