0.3 - Programming of the prices and coins 

 
This optión allows the changement of the default prices of use set in the software of the unit, as well as the value of each 
coin slot. First of all, you must program the prices of use and after you indicate the value for each one of the slots installed 
in the unit. When you change the prices of use, remember to change also the stickers above the coin entries which indicate 
the price to pay.  

 
Important note: 

To activate the use of the unit, you can use any of the coins acccepted by the coin salots. For example, you can program the 
ful operation at 1,20€ (supposing that the slots present in the unit are of 1€ and 0,2€). In this case, the user must insert a 
coin of each type, or six coins of 0,2€, until completing the amount for the fulloperation. 
 
In the following example, the unit is set to 1€ for the full operation, 0,40€  for the partial operation, and the slots present in 
the unit are of  1€ for slot 1 and 0,20€ for slot 2: 

Key 

Function to execute or select 

Terminal Display  

'Z' or 'ESC'  Goes to option 0 of the main menu. 

MAIN MENU: 
0-SYSTEM ADJUSTMENTS  

SPACE=NEXT 

ENTER=SELECT 

Select the system adjustments 

SUB-MENU SYSTEM: 

0.0-MEMORY RESET 
SPACE=NEXT 

ENTER=SELECT 

Select the programming of the price. The display shows the price for 
the full operation currently programmed. This price is correct in our 
example, so you press “ENTER” to go to the next screen. 

INDICATE PRICE 1 IN 

EUROS 
AND PRESS ENTER: 01,00 

 

ENTER 

The display shows now the price for the partial operation currently 
programmed. 

INDICATE PRICE 2 IN 

EUROS 

AND PRESS ENTER: 00,20 
 

0040 

Program  0,40€. 

INDICATE PRICE 2 IN 

EUROS 

AND PRESS ENTER: 00,40 

 

ENTER 

Now the unit asks the value for the coin of slot 1 (slot on the right 
handside, first channel for coins) 

INDICATE THE VALUE OF 

CHANEL 1 IN EUROS 

AND PRESS ENTER: 1,00 

 

ENTER 

When pressing ENTER, the screen shows the value for the coin of 
slot 2 (slot on the left hanside, second chanel for coins). 

INDICATE THE VALUE OF 

CHANEL 2 IN EUROS 

AND PRESS ENTER: 0,10 

 

020 

Indicate that chanel 2 for coins is of 0,2€ 

INDICATE THE VALUE OF 

CHANEL 2 IN EUROS 

AND PRESS ENTER: 0,20 

 

ENTER 

When pressing ENTER, the screen shows the value for the coin of 
slot 3 (third chanel for coins).  If the unit has got an electronic coin 
validator, repeat the process depicted above to indicate the value of 
each chanel for coins. If not, press “ENTER” until quit the option of 
price and coins programming. 

INDICATE THE VALUE OF 
CHANEL 3 IN EUROS 

AND PRESS ENTER: 0,00 

 

ENTER 

... 

 

ENTER 

Once the process is finished, the program goes back to option 3 of 
the system adjustments sub-menu. 

SUB-MENU SYSTEM: 

0.3-PRICES 

SPACE=NEXT 
ENTER=SELECT 

Summary of Contents for K7

Page 1: ...Keito K7 Technical and maintenance Manual INT 022EN 02 Revision I 24 09 2010 Page 1 of 43 MULTIFUNCTION K7 Technical Manual...

Page 2: ...going to the computer 10 Switch the K7 on It is ready for use B Operating in the Advanced Programming Mode B 1 Description of the programming terminal The terminal has got an LCD screen with 4 lines o...

Page 3: ...in menu if you press the SPACE key the options of the current sub menu will appear If when in a sub menu you press the ENTER key the program will execute the selected function If when in a sub menu yo...

Page 4: ...Blood pressure measurement 1 Pressure calibration 2 Pressure continuous measurement 3 Pressure adjust 3 Escapement test 0 Impedance Test 1 Body fat calibration 4 Body fat and heart rate adjust 2 Heart...

Page 5: ...tarts the memory reset RESETTING THE MEMORY Once the reset is finished the program goes back to option 0 of the system adjustments sub menu SUB MENU SYSTEM 0 0 MEMORY RESET SPACE NEXT ENTER SELECT The...

Page 6: ...n if they don t belong to the pharmacy Prints the uses with smart card in the collection report Flag n 4 0 Format of the date DD MM YY Day Month Year 1 Format of the date MM DD YY Month Day Year 2 For...

Page 7: ...x confirmation on the body fat measurement Prints the graphic of the heart rate analysis horizontally 4 Always measures the body fat 5 Body fat only in full operation The user must confirm the sex on...

Page 8: ...sks once more Insert another coin 6 Once the minimum amount is reached the unit does not ask to insert more coins 7 Even if the minimum amount for use has been reached the unit asks once more Insert a...

Page 9: ...cle disabled 6 The measure of the body fat is cancelled if the user steps off the platform without indicating the sex 7 Waits for the user to indicate the sex after the fat measure does not abort the...

Page 10: ...flags The display show the uccrent value of the first flag INDICATE THE VALUE OF FLAG 1 3 AND PRESS ENTER ENTER Press ENTER until you get the flag number that you wish to modify in this example we wis...

Page 11: ...ET SPACE NEXT ENTER SELECT 3 Select the programming of the price The display shows the price for the full operation currently programmed This price is correct in our example so you press ENTER to go t...

Page 12: ...ight B press 5 Value in uros 9 0 Contabilized uros 9 4 Cummulated Weight and height 15 Weight height B press 10 Value in uros 16 0 Contabilized uros 16 4 Example of a collection ticket of a unit progr...

Page 13: ...eport and the program goes back to the system adjustments sub menu SUB MENU SYSTEM 0 5 MAINTENANCE SPACE NEXT ENTER SELECT 0 6 Coin selector test This option allows the correct detection and operation...

Page 14: ...Clear the counters The collection report has got two counters one is set to zero every time that a report is printed but the other one the cumulated keeps the total number of coins The only way to set...

Page 15: ...Z or ESC Goes to option 0 of the main menu MAIN MENU 0 SYSTEM ADJUSTMENTS SPACE NEXT ENTER SELECT 1 Select the height system adjustments SUB MENU HEIGHT 1 0 RESET SPACE NEXT ENTER SELECT 0 Option 0 r...

Page 16: ...mory when making a memory reset This adjustment will only be necessary if for any reason the inner height of the unit needs to be changed During the autotest process the unit makes an autozero of the...

Page 17: ...the frequency is modified Let us suppose that we want to set the frequency to 52 29 kHz Proceed as follows Key Function to execute or select Terminal Display Z or ESC Goes to option 0 of the main menu...

Page 18: ...SC Goes to option 0 of the main menu MAIN MENU 0 SYSTEM ADJUSTMENTS SPACE NEXT ENTER SELECT 2 Select the weight system adjustments SUB MENU WEIGHT 2 0 RESET SPACE NEXT ENTER SELECT 0 Option 0 resets a...

Page 19: ...tc since they can cause wrong measurements to the system Proceed as follows Key Function to execute or select Terminal Display Z or ESC Goes to option 0 of the main menu Make sure that there isn t any...

Page 20: ...steps The unit measures the value of the atmospheric pressure In this moment you must not apply any pressure to the sensor and the valve of the rubber bulb must be open A pressure of 200 mmHg is appl...

Page 21: ...ometer and let the cuf deflate in full SUB MENU PRESSURE 3 1 CALIBRATION SPACE NEXT ENTER SELECT 3 2 Verify Pressure This option makes different continuous pressure measurements and shows them in the...

Page 22: ...the decay rate 3 When the pressure is 50mmHg a ticket is printed with the elapsed time since the pressure was 250mmHg until reaching 50mmHg and with the maximum and minimum decay rate registered 4 Dur...

Page 23: ...he main menu MAIN MENU 0 SYSTEM ADJUSTMENTS SPACE NEXT ENTER SELECT 4 Select the body fat adjustments SUB MENU FAT PULSE 4 0 IMPEDANCE TEST SPACE NEXT ENTER SELECT 0 This option measures the impedance...

Page 24: ...mation In this case the electrodes record the electrical activity of the heart and from these signals the heart rate is measured At the end of the test the unit prints a ticket with the value of the p...

Page 25: ...Keito K7 Technical and maintenance Manual INT 022EN 02 Revision I 24 09 2010 Page 25 of 43 Heart rate analysis Heart rate 86 1 P mn maximum Rate 90 P mn minimum Rate 83 P mn...

Page 26: ...tial autotest and detects any malfunction Proceed as follows Key Function to execute or select Terminal Display Z or ESC Goes to option 0 of the main menu MAIN MENU 0 SYSTEM ADJUSTMENTS SPACE NEXT ENT...

Page 27: ...ADJUSTMENTS SPACE NEXT ENTER SELECT 5 Select the printer adjustments SUB MENU PRINTER 5 0 RESET SPACE NEXT ENTER SELECT 1 Select the paper feed Make sure that the paper comes up centered and straight...

Page 28: ...the programme goes back to option 3 of the printer adjustment sub menu SUBMENU PRINTER 5 3 TEST Num 2 SPACE NEXT ENTER SELECT 5 4 Printer test n 3 This option starts the printer and prints simulated...

Page 29: ...n 5 of the printer adjustment sub menu SUB MENU PRINTER 5 5 CUTTER TEST SPACE NEXT ENTER SELECT 5 6 Temperature of the printer This test shows the status of the printer head without printing Proceed a...

Page 30: ...PACE NEXT ENTER SELECT 6 1 Programming the time Suppose that you wish to program 13 00 00 h Proceed as follows Key Function to execute or select Terminal Display Z or ESC Goes to option 0 of the main...

Page 31: ...he memory SUB MENU DATE TIME 6 2 DATE SPACE NEXT ENTER SELECT Note If during the time programming you need to cancel the process press the ESC key The keys and let you move the cursor through the disp...

Page 32: ...left Moves the cursor to the right If you wish a double wide character press this key before the desired character CRTL C This combination does the same function as ENTER but it also centers the text...

Page 33: ...if a card belongs to that premise or group of premises or not erase the data contained in the card charge new credits and list the recorded measurements and or the identification data of the card If...

Page 34: ...the program goes back to option 1 of the smart card sub menu SMART CARD 8 1 CARD RESET SPACE NEXT ENTER SELECT 8 2 Programming the credit in the smart card This option is very similar to the previous...

Page 35: ...ELECT 9 Voice Buzzer Test Option 9 of the main menu With this option we can check the correct operation of the audio system of the unit as well for the buzzer as for the voice messages The volume of t...

Page 36: ...Function to execute or select Terminal Display Z or ESC Goes to option 0 of the main menu MAIN MENU 0 SYSTEM ADJUSTMENTS SPACE NEXT ENTER SELECT 9 Select the voice and buzzer test SUB MENU VOICE BUZZ...

Page 37: ...g is allright the menu goes to the previous screen In case of error the screen would be the one beside MODEM NOT RESPONDING PRESS ANY KEY TO END 10 1 Reset step by step This option is similar to the p...

Page 38: ...case of error the screen would be the one beside MODEM NOT RESPONDING PRESS ANY KEY TO END 10 3 Central telephone With this option you indicate to the unit which is the telephone number of the Data Ce...

Page 39: ...er of SMS to be deleted ERASE SMS INDICATE SMS NUMBER 01 ENTER If the SMS has been deleted correctly the message beside appears Press any key to continue or ENTER to end MESSAGE 1 DELETED Any Key The...

Page 40: ...SMS SENDING SMS If the SMS has been sent succesfully the following message will appear SMS SENT TO DATA CENTER Any Key By pressing any key the system goes back to the selected option SUBMENU GSM SMS A...

Page 41: ...Parameter 1 Parameter 1 indicates if the unit can send an SMS when switched on or when an error is detected Value Description Description 0 Does NOT send an SMS when unit is switched on 1 Sends SMS wh...

Page 42: ...tion 0 Will never send an SMS for this reason 200 Sends an SMS with all data of status and collection and clears the collection counters when collection is 200 your currency etc Parameter 6 The unit w...

Page 43: ...essary to inflate over 300 mmHg to measure the blood pressure 2 It was not possible to inflate the cuff Possible puncture in the cuff 3 Deflated up to 60mmHg without detecting impulsions 4 Before havi...

Reviews: