Model 2010

Multimeter

Quick Reference Guide

A   G R E A T E R

M E A S U R E   O F   C O N F I D E N C E

Summary of Contents for 2010

Page 1: ...Model 2010 Multimeter Quick Reference Guide A G R E A T E R M E A S U R E O F C O N F I D E N C E...

Page 2: ......

Page 3: ...Model 2010 Multimeter Quick Reference Guide 1996 Keithley Instruments Inc All rights reserved Cleveland Ohio U S A Second Printing February 2001 Document Number 2010 903 01 Rev B...

Page 4: ...ly into the manual Addenda are numbered sequentially When a new Revision is created all Addenda associated with the previous Revision of the manual are incorporated into the new Revision of the manual...

Page 5: ...Table of Contents Safety Precautions 1 Introduction 5 Front Panel Operation Summary 7 Remote Operation Summary 25...

Page 6: ......

Page 7: ...ained Operators use the product for its intended function They must be trained in electrical safety procedures and proper use of the instrument They must be protected from electric shock and contact w...

Page 8: ...10 are Installation Category II All other instruments signal terminals are Installation Category I and must not be connected to mains Do not connect switching cards directly to unlimited power circuit...

Page 9: ...fire hazard Chassis connections must only be used as shield connec tions for measuring circuits NOT as safety earth ground connections If you are using a test fixture keep the lid closed while power...

Page 10: ...as long as they are equivalent to the original component Note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and functional ity of the product If you ar...

Page 11: ...roduction This quick reference guide includes summary informa tion on front panel and remote operation for the Model 2010 Multimeter For detailed operating information consult the Model 2010 User s Ma...

Page 12: ...6...

Page 13: ...FT and then SAVE 3 Use the and keys to select YES Select NO if you do not wish to change the user setup that is stored in memory 4 Press ENTER To restore factory or user settings 1 Press SHIFT and the...

Page 14: ...LO SENSE 4 WIRE INPUTS 350V PEAK 1100V PEAK AUTO RANGE R Model 2010 Measure DCV ACV 2 FREQ PERIOD or TC TEMP Thermocouple TC Temperature measurements are typically performed through a thermocouple sc...

Page 15: ...desired measure ment function 3 Use the RANGE keys to select autoranging or a manual range Pressing the AUTO range key tog gles autoranging You can select a different range with the and RANGE keys 4 T...

Page 16: ...rd deviation average minimum and maximum 3 Use the EXIT key to return to the normal display Changing speed resolution and filter RATE Measurement speed reading RATE can be changed for any measurement...

Page 17: ...sions Changing temperature measurement configuration Press SHIFT and then SENSOR Three choices are avail able using the and keys UNITS C K F Specify units SENSOR TCOUPLE or 4W RTD Specify sensor type...

Page 18: ...b Where X is the normal display reading m and b are the user entered constants Y is the displayed result Percent Where Input is the normal display reading Reference is the user entered constant Percen...

Page 19: ...There are two sets of limits The first set is LL1 low limit 1 and HL1 high limit 1 The second set is LL2 low limit 2 and HL2 high limit 2 Typically the limit 1 test range is used to check for tight to...

Page 20: ...lifting the probes Pressing SHIFT and then HOLD a second time disables hold Dry circuit testing This feature lets you make low resistance measurements on contact devices such as switches and relay co...

Page 21: ...may occur While in DC volts DCV select ratio by pressing SHIFT and then RATIO Use the and keys to tog gle RATIO to ON and SENSIN to OFF The display will read RA for ratio Measure DCV using SENSE term...

Page 22: ...ble before the device action measurement occurs It can be set man ually or an auto delay can be used To set a delay press SHIFT and then DELAY Use the and keys to select AUTO or MANual If MANual is ch...

Page 23: ...will cause the previously closed chan nel to open For the 4 function CLOSE will close the selected channel and the paired channel Paired chan nels for the Model 2000 SCAN are 1 6 2 7 3 8 4 9 and 5 10...

Page 24: ...C Diode test Digits Range Rate Frequency and Period Digits Range Relative Value Rate Function GPIB Address Language Key click Limits Beeper High limit 1 Low limit 1 High limit 2 Low limit 2 mx b Scale...

Page 25: ...elay Source Voltage AC and DC dB reference dBm reference Digits AC Digits DC Filter Count Mode Range Relative Value Rate AC Rate DC Ratio DC Sensein Off 1 0 7 On 10 Moving average Auto Off 0 0 Medium...

Page 26: ...l program name Cannot create program Expression error Hardware missing Data corrupt or stale Out of memory Illegal parameter value Too much data Parameter data out of range Settings conflict Parameter...

Page 27: ...or Invalid character Command error EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE 000 No error SE 101 121 122 123 124 125 126 161 171 174 301 302 303 304 305 306 307 308 309 310 311...

Page 28: ...e error 100k 4 w full scale error 1M 4 w full scale error 10M 4 w full scale error 10m adc zero error 100m adc zero error 10m adc full scale error 100m adc full scale error 1 adc full scale error Date...

Page 29: ...10 Ohm 4 w Ioff Ocomp DryCkt FS error 1K Ohm Ioff Ocomp FS error 100 Ohm 4 w Ioff Ocomp DryCkt FS error 10K Ohm Ioff Ocomp FS error Front rear switch incorrect Calibration data invalid Reading buffer...

Page 30: ...is 4 DDC Maximum Channel is 8 DDC Calibration Locked DDC Conflict Error DDC No Remote Error DDC Mode IDDC Error DDC Mode IDDCO Error Keithley 199 Serial Poll Byte Events DDC Ready DDC Reading Done DD...

Page 31: ...196 199 The configuration menu is accessed by pressing SHIFT and then GPIB Commands for the SCPI language are provided in Tables 4 through 15 The DDC commands for the 199 and 196 languages are provide...

Page 32: ...Standard Event Status Enable Register PON Power On URQ User Request CME Command Error EXE Execution Error DDE Device Dependent Error QYE Query Error OPC Operation Complete Logical AND OR Logical OR OP...

Page 33: ...g B5 Meas B4 B3 B2 B1 B0 Operation Event Register B15 B11 Idle B10 B9 B8 B7 B6 Trig B5 Meas B4 B3 B2 B1 B0 Operation Event Enable Register To Operation Summary Bit OSB of Status Byte Register See Figu...

Page 34: ...To Measurement Summary Bit MSB of Status Byte Register See Figure 6 B15 B12 B10 B9 B8 B7 B6 RAV B5 HL2 B4 LL2 B3 B2 LL1 B1 B0 Measurement Condition Register BFL HL1 ROF BFL ROF BHF BAV B10 B9 BHF B8...

Page 35: ...ion Summary Temp Temperature Summary Logical AND OR Logical OR 0 B13 B9 B14 B8 B15 0 Warn Cal Questionable Event Register B13 B9 B14 B8 B15 To Questionable Summary Bit QSB of Status Byte Register See...

Page 36: ...er Service Request Enable Register OSB Operation Summary Bit MSS Master Summary Status RQS Request for Service ESB Event Summary Bit MAV Message Available QSB Questionable Summary Bit EAV Error Availa...

Page 37: ...ble Register Read the Standard Event Enable Register and clear it Returns the manufac turer model number serial number and firm ware revision levels of the unit Set the Operation Com plete bit in the...

Page 38: ...to continue com mand Programs the Service Request Enable Register Reads the Service Request Enable Register Reads the Status Byte Register Sends a bus trigger to the 2010 Performs a checksum test on R...

Page 39: ...in the program message 3 Upper case characters indicate the short from ver sion for each command word Table 9 ROUTe command summary Table 5 Signal oriented measurement commands Command Description CO...

Page 40: ...gh Z Query mx b units Set target value for PERCent calculation 100e6 to 100e6 Use input signal as target value Query percent Enable or disable kmath calcula tion Query state of kmath function Read res...

Page 41: ...Note ON is the RST default parameter and OFF is the SYSTem PRESet default Table 7 DISPlay command summary Command Description Default param SCPI DISPlay WINDow 1 TEXT DATA a DATA STATe b STATe ENABle...

Page 42: ...e OPEN ALL MULTiple CLOSe list STATe OPEN list SCAN INTernal list INTernal EXTernal list EXTernal LSELect name LSELect Commands to control scanner card Close specified channel 1 to 10 or channel pair...

Page 43: ...sh reading Path to control Hold feature Set Hold window 0 01 to 20 Query Hold window Set Hold count 2 to 100 Query Hold count Enable or disable Hold Query state of Hold Path to configure AC current Se...

Page 44: ...o configure measure ment range Select range 0 to 3 1 Query range Enable or disable auto range Query auto range Specify reference 3 1 to 3 1 Enable or disable reference Query state of reference Use inp...

Page 45: ...Query filter type Specify filter count 1 to 100 Query filter count Enable or disable filter Query state of digital filter Path to configure bandwidth Specify bandwidth 3 to 300e3 Query bandwidth Path...

Page 46: ...erminals 10 1 to 10 1 Enable or disable sense terminal reference REL Query sense terminal ref erence REL state Use and save sense termi nal input as new reference Query sense terminal refer ence REL v...

Page 47: ...its AVERage TCONtrol name TCONtrol COUNt n COUNt STATe b STATe Path to configure four wire resistance Set integration rate line cycles 0 01 to 10 Query line cycle integration rate Path to configure me...

Page 48: ...1372 Enable or disable reference Query state of reference Use input signal as reference Query reference value Specify measurement resolu tion 4 to 7 Query resolution Path to configure and control the...

Page 49: ...ecify BETA value 0 to 1 00 Query BETA value Specify DELTa value 0 to 5 00 Query DELTa value PT100 100 00 0 00385 0 11100 1 50700 FREQuency THReshold VOLTage RANGe n RANGe REFerence n STATe b STATe ACQ...

Page 50: ...reshold resistance 1 to 1000 Query threshold resistance 10 Note REPeat is the RST default and MOVing is the SYSTem PRESet default Table 11 STATus command summary Command Description Default param SCPI...

Page 51: ...CLS and STATus PRESet are explained by the following notes 2 Event Registers Power up and CLS Clears all bits of the registers STATus PRESet No effect 3 Enable Registers Power up and STATus PRESet Cle...

Page 52: ...ing the Error Queue Power up and CLS Clears the Error Queue RST SYSTem PRESet and STATus PRESet No effect Table 13 TRACe command summary Command Description Default param SCPI TRACe DATA CLEar FREE PO...

Page 53: ...yer Set measure count 1 to 9999 or INF Query measure count Set delay 0 to 999999 999 sec Enable or disable auto delay Query state of delay Query delay Select control source IMMediate TIMer MANual BUS...

Page 54: ...tage units Select ACV measurement units V DB or DBM Path to set DB reference voltage Specify reference in volts 1e 7 to 1000 Query DB reference Path to set DBM reference impedance Specify reference im...

Page 55: ...k 10V 1V 100V 100V 3A 3A 100k 100V 10V 1000V 750V 3A 3A 1M 750V 100V 1000V 750V 3A 3A 10M 750V 750V 1000V 750V 3A 3A 100M 750V 1000V 750V 3A 3A 100M 750V 2 wireand4 wireohms Zero rel Z0 Z1 Z2 Zero dis...

Page 56: ...prefix Reading without prefix Reading and buffer location with pre fix Reading and buffer location without prefix Reading and channel with prefix Reading and channel without prefix Reading buffer loc...

Page 57: ...imulated temperature set by H0 Multiplex A0 A1 Auto Cal multiplex disabled Auto Cal multiplex enabled Delay Wn n delay period in milliseconds 0msec to 999999msec Display Da D Display up to 12 characte...

Page 58: ...max channel is 2 Scan mode max channel is 3 Scan mode max channel is 4 Scan mode max channel is 5 Scan mode max channel is 6 Scan mode max channel is 7 Scan mode max channel is 8 Scan mode max channe...

Page 59: ......

Page 60: ...of Keithley Instruments Inc All other trademarks and trade names are the property of their respective companies Keithley Instruments Inc 28775 Aurora Road Cleveland Ohio 44139 440 248 0400 Fax 440 24...