D3DP 3xx/x
Diagnosis
Project engineering manual V1.00
60
© KEBA
8
Diagnosis
8.1
Flashing code
The yellow LED has only during software update a defined function.
LED yel
low
LED red
LED green
State axis
long
(0,8 s)
long
(0,8 s)
1)
short
(0,4 s)
2)
On
On
On
Restart / starting or loading
firmware update
Self initialization during device start
up
Off
1 x
1 x
Not ready (to switch on)
Off
2 x
2 x
Switch on disabled
Off
3 x
3 x
Axis ready (Ready to switch on)
Off
4 x
4 x
Axis switched on
Off
5 x
5 x
Operation enabled
Off
6 x
6 x
Quickstop
Error code
7 x
7 x
Fault reaction active
Error code
8 x
8 x
Error
1)
LED green long = in standby mode
2)
LED green short = control active
Summary of Contents for D3DP 3 Series
Page 1: ...D3 DP 3xx x Supply module Project engineering manual V 1 00 Translation of original manual ...
Page 4: ...D3 DP 3xx x Project engineering manual V1 00 4 KEBA ...
Page 8: ...D3 DP 3xx x Table of Contents Project engineering manual V1 00 8 KEBA ...
Page 75: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 75 KEBA ...
Page 76: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 76 KEBA ...
Page 77: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 77 KEBA ...
Page 80: ...D3 DP 3xx x Glossary Project engineering manual V1 00 80 KEBA Glossary ...
Page 81: ...D3 DP 3xx x Index Project engineering manual V1 00 81 KEBA Index ...
Page 82: ...D3 DP 3xx x Index Project engineering manual V1 00 82 KEBA ...