D3DP 3xx/x
Connections and wiring
Project engineering manual V1.00
47
© KEBA
Illustration 624: EtherCAT terminal (X40A / X40B)
For shielded connection up to a length of ≤ 20 m the following tested cable
or an equivalent cable must be used:
●
"Silverline Gold" Cat. 7 patch cable, S/STP 4x2x0,14 mm
2
, twisted pair
and shielded data cable with characteristic impedance R
w
= 100 Ω ±15
%
Information
For cable lengths ≥ 20 m special installation cables with larger crosssec
tions are to be used.
All modules (axis and supply modules) have enclosed suitable EtherCAT
cables. They can be used for a connection to the left, nearby module.
Description
Terminal
Specification
X40A EtherCAT IN input
EtherCAT
X40A
Connection via RJ45 connec
tor
X40B EtherCAT OUT output
EtherCAT
X40B
6.6
Specification connection "State" (X20A)
Designation
Terminal
Details
X20A
●
RO0 2 = normally
closed contact
●
RO0 4 = changeover
contact
●
RO0 1 = normally open
contact
●
Relay contact: ≤ 50 V
AC max. 0.5 A(ohmic
load)
●
Contact freely program
mable
●
Factory setting = Active
on Error
Summary of Contents for D3DP 3 Series
Page 1: ...D3 DP 3xx x Supply module Project engineering manual V 1 00 Translation of original manual ...
Page 4: ...D3 DP 3xx x Project engineering manual V1 00 4 KEBA ...
Page 8: ...D3 DP 3xx x Table of Contents Project engineering manual V1 00 8 KEBA ...
Page 75: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 75 KEBA ...
Page 76: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 76 KEBA ...
Page 77: ...D3 DP 3xx x Declaration of conformity Project engineering manual V1 00 77 KEBA ...
Page 80: ...D3 DP 3xx x Glossary Project engineering manual V1 00 80 KEBA Glossary ...
Page 81: ...D3 DP 3xx x Index Project engineering manual V1 00 81 KEBA Index ...
Page 82: ...D3 DP 3xx x Index Project engineering manual V1 00 82 KEBA ...