Operating Instructions CDF3000
4-3
4 Commissioning
DE
EN
FR
IT
ES
FR
4.2
Serial commis-
sioning
Apply this mode of commissioning when you want to commission several
identical drives (i.e. serial commissioning). The same positioning control-
ler and motor must be set for each drive in an identical application.
If you already have a complete dataset available, please skip the para-
graph "Saving dataset to SmartCard" (with KP200XL) or
from unit to file" (with D
RIVE
M
ANAGER
).
4.2.1 Serial commis-
sioning with
K
EY
P
AD
Prerequisite:
• All positioning controllers are completely connected.
• The
first
drive has already been fully taken into operation.
• The K
EY
P
AD
is directly plugged onto the positioning control (X4) via a
RS232 interface.
Attention:
The CARD-menu can only be selected as long as the
drive
is not active
!
Saving dataset to S
MART
C
ARD
Step
Action
Comment
Representation
1
Connect the K
EY
P
AD
to the positioning controller of
the
first
drive, insert a S
MART
C
ARD
and switch on
the mains supply.
2
Select the CARD menu.
= load/save with the
S
MART
C
ARD
3
Choose WRITE.
= save dataset
4
Choose ALL and
start the save operation with
the
Start/Enter key.
= complete dataset
will be saved
5
READY is displayed.
= saving completed
without errors
With this process you have written your dataset to a S
MART
C
ARD
.
CARD
CARD
CARD
CARD
CARD
start
enter
start
enter
start
enter
stop
return
stop
return
Summary of Contents for CDF3000
Page 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Page 12: ...Operating Instructions CDF3000...
Page 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Page 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Page 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Page 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...