5-4
Operating Instructions CDF3000
5 Troubleshooting
5.3
User errors in
K
EY
P
AD
opera-
tion
5.4
User errors in
S
MART
C
ARD
oper-
ation
Error
Cause
Remedy
ATT1
Parameter cannot be changed at current
user level or is not editable
Select user level 1-MODE higher.
ATT2
Motor must not be controlled via the CTRL
menu
Cancel start signal from a
different control location.
ATT3
Motor must not be controlled via the CTRL
menu because of error state
Reset error.
ATT4
New parameter value impermissible
Change value.
ATT5
New parameter value too high
Reduce value.
ATT6
New parameter value too low
Increase value.
ATT7
Card must not be read in current state
Reset start signal.
ERROR
Invalid password
Enter correct password.
Table 5.2
User errors K
EY
P
AD
: Reset with
start/enter
Error
Meaning
Remedy
ERR91
S
MART
C
ARD
write-protected
Use different
S
MART
C
ARD
ERR92
Error in plausibility check
ERR93
S
MART
C
ARD
not readable, wrong positioning controller
type
ERR94
S
MART
C
ARD
not readable, parameter not compatible
ERR96
Connection to S
MART
C
ARD
interrupted
ERR97
S
MART
C
ARD
data invalid (checksum)
ERR98
Insufficient memory on S
MART
C
ARD
ERR99
Selected area not present on S
MART
C
ARD
, no parameters
transferred from S
MART
C
ARD
Table 5.3
S
MART
C
ARD
error: Reset with
stop/return
Summary of Contents for CDF3000
Page 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Page 12: ...Operating Instructions CDF3000...
Page 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Page 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Page 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Page 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...