4
Supplements to the operation manual 1040.00B.4-00 CDF3000
Operation Manual CDF3000
ID no.: 1040.20B.5-00 Date: 02/2022
Supplements to the operation manual 1040.00B.4-00 CDF3000
01.6.1 Monitoring of the external braking resistor
The temperature of the braking resistor is to be monitored.
If the braking resistor overheats, the device must be immediately disconnected from the
mains by means of suitable measures and the power stage deactivated.
01.7 Rating plate
Industrial Automation
Germany GmbH
35633 Lahnau
In:
Out:
Type:
CDF30.008,C2.5
DC 24-48 V
10 A
3x0-33 V 8 A
480 VA 0-400 Hz
CDF30.008 ,C2.5
25
Industrial Automation
Germany GmbH
35633 Lahnau
Type:
Rev.
213702782
SN:
Data Set:
213702782
SN:
Material-Nr.:
10549020
Material-Nr.:
10549020
Serien-Nr.
Serial no.
Kalenderwoche
Calendar week
Jahr
Year
Figure 01.1 Rating plate CDF3000 (example)
01.8 Relevant laws and standards applied
01.8.1 Ecodesign Regulation
Note:
From July 2021 the Ecodesign Regulation also applies to speed controllers
(EU)2019/1781 (efficiency class IE2). The KEBA drive controllers described
here do not fall under this regulation because at least one of the following
points applies if used as intended:
y
Operation exclusively for servomotors with speed/position feedback
y
Supply with DC voltage
y
Supply with single-phase AC voltage
y
Supply with low voltage <100 V
01.8.2 Standards applied
On this topic, also see chapter “01.9 CE declaration”.
Summary of Contents for CDF3000
Page 1: ...Positioning controller Rated current 8 A Power supply 24 48 V DC CDF3000 Operation Manual...
Page 12: ...Operating Instructions CDF3000...
Page 16: ...1 4 Operating Instructions CDF3000 1 Safety...
Page 54: ...3 34 Operating Instructions CDF3000 3 Installation...
Page 78: ...4 24 Operating Instructions CDF3000 4 Commissioning...
Page 84: ...5 6 Operating Instructions CDF3000 5 Troubleshooting...