29
The salt solution in the salt tank is regener-
ated. The process is completed within XXX
minutes. There can be no regeneration of
the base exchanger before then.
There was an error in the base exchanger.
Reverse Osmosis is ready.
The prerinse of the RO membrane will be
completed in X seconds.
The reverse osmosis produces permeate.
The final rinse of the RO membrane will be
completed in XX seconds.
Permeate production blocked as the base
exchanger is performing a regeneration.
No water pressure at inlet of the system.
Buffer container for permeate filled with
permeate to the level sensor BUFFER
CONTAINER FULL.
Water level in the buffer container for per-
meate is below level sensor BUFFER
CONTAINER FULL.
Water level in the buffer container for per-
meate is below level sensor BUFFER
CONTAINER EMPTY.
Dry run delay active after XXX minutes.
During this period, the SB-C is supplied
with cold water.
The buffer container for permeate is empty,
the SB-C is supplied with cold water.
Here, the operaing hours of the individual
system components since system start-up
are shown.
The different menu items are shown in the
overview at the beginning of this chapter.
The bases of a safe operating of the equip-
ment is thr regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggested by him, such as
– parts and wearing parts,
– accessories parts,
– operating materials,
– cleaning agents.
DANGER
Risk of accident while working on the unit!
During all tasks:
Turn off the water supply; close the
fresh water tap,
First switch-on in voltage-less state,
switch off the emergency stop switch in
the building and secure it against being
switched on again.
ATTENTION
Risk of damage. Never use a high-pressure
jet to clean the inside of the system.
–
Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the
washing system.
–
Customer Service
Work designated with the sign “Cus-
tomer Service” may only be done by the
fitters of Kärcher Customer Service.
In order to ensure a reliable operation of the
plant, we recommend that you conclude a
maintenance contract with us. Please refer
to you local KÄRCHER service depart-
ment.
DANGER
Risk of injury due to high-pressure jet exit-
ing possibly defective components, risk of
burns due to hot plant parts. When working
on the opened plant, proceed with particu-
lar care and observe all safety instructions.
The following parts are possible to be hot-
ter than 50 °C:
– exhaust pipe and exhaust opening
– Burner inclusive flow-type heater
– cylinder head of the high pressure
pump
– high pressure hose
Operating hours
Maintenance instructions
Who may perform maintenance?
Maintenance contract
31
EN
Summary of Contents for SB MB
Page 1: ...SB MB 59638780 04 17...
Page 2: ...2...
Page 10: ...8 1 Menu item 2 Parameter 10 EN...
Page 29: ...27 29 EN...
Page 50: ...48 SB MB standard SB MB comfort Dimension drawing for CAB model 50 EN...
Page 51: ...49 SB MB standard SB MB comfort Dimension drawing for SKID model 51 EN...
Page 52: ...50 Dimension drawing for SKID model with WSO upgrade kit 52 EN...