35
Faults shown in the display
Display
Cause
Remedy
F 001
Electronic outlets overloaded
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 004
Dimming sensor defective
Call customer service.
F 005
Protective motor switch on high pressure pumps was triggered
Reset motor protection switch; call Customer Ser-
vice if the problem recurs.
F 006
Connection to RDS defective
Call customer service.
F 007
The pressure switch for air on the compressor does not report any
pressure
Check the compressor and the compressed air
lines.
F 008
Cause: no connection to the electronics "MSWS".
Check the plug connection of the data cable with
electronics A1
F 010
No connection to pump electronics at washing station 1
Call customer service.
F 011
Electronic outlets at washing station 1 overloaded
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 012
Current pickup of high pressure pump at washing station 1 too high
F 013
Current pickup of high pressure pump at washing station 1 too low
See "Faults on high pressure pumps"
F 014
Contact of high pressure pump at washing station 1 stuck
Call customer service.
F 016
Coiling protection contact of high pressure pump washing station 1 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 017
Oil level of high pressure pump at washing station 1 too low
Refill oil, acknowledge the fault.
F 018
Electronics at washing station 1 defective
Call customer service.
F 020
No connection to remote control electronics at washing station 1
Check the connector of the data cable with the elec-
tronics of the remote control.
F 021
Fault at coin acceptor at washing station 1
Call customer service.
F 022
Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 030
No connection to pump electronics at washing station 2
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 031
Electronic outlets at washing station 2 overloaded
F 032
Current pickup of high pressure pump at washing station 2 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 033
Current pickup of high pressure pump at washing station 2 too low
See "Faults on high pressure pumps"
F 034
Contact of high pressure pump at washing station 2 stuck
Call customer service.
F 036
Coiling protection contact of high pressure pump washing station 2 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 037
Oil level of high pressure pump at washing station 2 too low
Refill oil, acknowledge the fault.
F 038
Electronics at washing station 2 defective
Call customer service.
F 040
No connection to remote control electronics at washing station 2
Check the connector of the data cable with the elec-
tronics of the remote control.
F 041
Fault at coin acceptor at washing station 2
Call customer service.
F 042
Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 050
No connection to pump electronics at washing station 3
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 051
Electronic outlets at washing station 3 overloaded
F 052
Current pickup of high pressure pump at washing station 3 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 053
Current pickup of high pressure pump at washing station 3 too low
See "Faults on high pressure pumps"
F 054
Contact of high pressure pump at washing station 3 stuck
Call customer service.
F 056
Coiling protection contact of high pressure pump washing station 3 has
triggered.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 057
Oil level of high pressure pump at washing station 3 too low
Refill oil, acknowledge the fault.
F 058
Electronics at washing station 3 defective
Call customer service.
F 060
No connection to remote control electronics at washing station 3
Check the connector of the data cable with the elec-
tronics of the remote control.
F 061
Fault at coin acceptor at washing station 3
Call customer service.
F 062
Check the microswitch on the mechanical coin ac-
ceptor, replace electronic coin acceptor
F 070
No connection to pump electronics at washing station 4
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 071
Electronic outlets at washing station 4 overloaded
F 072
Current pickup of high pressure pump at washing station 4 too high Acknowledge the fault. If the fault recurs, call cus-
tomer service.
F 073
Current pickup of high pressure pump at washing station 4 too low
See "Faults on high pressure pumps"
37
EN
Summary of Contents for SB MB
Page 1: ...SB MB 59638780 04 17...
Page 2: ...2...
Page 10: ...8 1 Menu item 2 Parameter 10 EN...
Page 29: ...27 29 EN...
Page 50: ...48 SB MB standard SB MB comfort Dimension drawing for CAB model 50 EN...
Page 51: ...49 SB MB standard SB MB comfort Dimension drawing for SKID model 51 EN...
Page 52: ...50 Dimension drawing for SKID model with WSO upgrade kit 52 EN...