47
Press the programme button and select
the function "Fill+Rinse clear" by turn-
ing the button in the direction of the ar-
row.
The control valve automatically moves
to the function "Operations". The salt
tank is filled with water.
When the water level is correct, fill the
salt tank with salt tablets according to
DIN 19604 (also see chapter on Acces-
sories).
The plant is ready for operations when
these jobs are completed. Conclude the
start-up activities by doing a soft water test.
During first start-up:
Fill the membrane with initial tap water
pressure (net it).
Rinse the memrane for 10 ... 20 min-
utes (foam formation during this proce-
dure is normal).
During fresh start-up after shutdown:
Let the rinsing run until there are no
bubbles to be seen at the throughflow
meter of the permeate.
1 Adjustment screw
Check the pressure of the detergent so-
lution.
Target value: 0.9...1.0 MPa (9...10
bars).
Adjust the pressure as needed by turn-
ing the adjustment screw.
Check burner setting.
Check all functions of the system.
Check all washing programmes on all
washing stations.
Check the plant for leaks; tighten
screws if required.
The initial startup of the gas burner must
only be performed by authorised expert
staff of the burner manufacturer.
– The device must be connected to a sep-
arate chimney.
– The exhaust system must be designed
according to the local rules and regula-
tions after consulting the concerned
chimney expert.
Type B23
Gas appliances without flow controller
where all parts of the exhaust system that
are subjected to excess pressure are free
of combustion air. The B23 installation
opens new options of connecting the appli-
ance to a traditional single-draught chim-
ney according to DIN 18160 and operating
it depending on the air conditions in the
room. The only requirement is that the
chimney must be suitable for being con-
nected to combustion devices (i.e. it has
been cleaned by inserting a stainless steel
pipe).
Refill / Clean washing
Filling the salt tank
Start-up of the RO plant
Check the pressure of rim cleaner
(option)
Check the function of the system
Starting up the gas burner (option)
Gas appliances with an exhaust
system that sucks out the combustion
air from the installation room
49
EN
Summary of Contents for SB MB
Page 1: ...SB MB 59638780 04 17...
Page 2: ...2...
Page 10: ...8 1 Menu item 2 Parameter 10 EN...
Page 29: ...27 29 EN...
Page 50: ...48 SB MB standard SB MB comfort Dimension drawing for CAB model 50 EN...
Page 51: ...49 SB MB standard SB MB comfort Dimension drawing for SKID model 51 EN...
Page 52: ...50 Dimension drawing for SKID model with WSO upgrade kit 52 EN...