14
Turn the main switch to position "0"
Turn the main switch to position "1".
Lock the operating time at the control.
Filling the fuel tank.
If the equipment is to be shut down, and
there is not danger of frost,
disconnect the water input,
disconnect the power supply.
Screw off water supply hose and high
pressure hose.
Remove the RO membrane and store it
under anti-freezing conditions.
Empty all swimmer containers; unscrew
the hoses and let the water drain off.
Empty the permeate buffer tank.
Disconnect the water pipe between
base exchanger and swimmer tank for
warm water.
Rinse the plant (without base exchang-
er) with an anti-frost solution.
Rinse the base exchanger with concen-
trated salt solution.
Unscrew both the hoses under the boil-
er and let the water drain off.
Blow out all water-carrying parts with
oil-free compressed air.
Note:
All parts of the plant except the base ex-
changer must be rinsed with anti-frost solu-
tion during longer operational breaks to
prevent the system against corrosion.
In case of doubt, call Customer Service to
carry out the shutdown operations.
Shutting down
Shutdown during Frost Conditions
Shutdown
Shutdown during frost period
16
EN