Wartung.pm6.5 - GB
Page 4.6
Maintenance
BOGE Operating instructions for CM 9 series screw compressor module
Clean or change
suction filter
Cleaning:
– 1x monthly,
however, at least every 500 operating hours.
– Correspondingly earlier if the air taken in is heavily soiled.
Change:
– In the event of damage.
– After the second cleaning.
– Switch off the compressor using the OFF button.
CAUTION: Risk of injury!
Switch off the main switch and secure against unintentional switching-on.
Removing the filter cartridge
– Remove lid
of the filter housing (see fig. 4.2).
– Remove filter cartridge
(see fig. 4.2).
ATTENTION!
Do not clean filter cartridges in liquids.
Do not use any hard objects when cleaning to avoid damaging the filter paper.
Refit a new filter cartridge in the event of damage or once it has been
cleaned twice.
– Hit on the filter cartridge using the palm of your hand to knock out coarse
dust.
– Blow out fine dust
from the inside to the outside
using dry compressed
air (maximum pressure 5 bar).
– Clean the sealing surface of the filter cartridge.
Fitting a filter cartridge
– Insert filter cartridge into the filter housing.
– Attach lid of the filter housing.
4.3
Regular maintenance work
Cleaning the filter
cartridge
Fig. 4.2: Changing the suction filter
1
2
Summary of Contents for BOGE CM9 Series
Page 1: ...Deutsch English Fran ais Italiano Espa ol Nederlands 5 963 387 0 08 09 BOGE CM9...
Page 2: ......
Page 3: ...Betriebsanleitung Schraubenkompressor Modul Baureihe CM 9...
Page 46: ...Operating instructions Screw compressor module Serie CM 9...
Page 89: ...Instructions de service Module pour compresseurs vis S rie CM 9...
Page 134: ...Modulo Compressore a vite Serie CM 9 Istruzioni per l uso...
Page 177: ...Instrucciones de uso Compresores de tornillo M dulo Serie constructiva CM 9...
Page 220: ...Bedrijfsvoorschrift Schroefcompressor module Serie CM 9...
Page 263: ......