Katherm HK
1.43
Ready-to-install trench heaters with EC tangential fan
Assembly and installation instructions
7
4. Alignment and positioning
4.1 Alignment using height-adjustment feet and raised floor
brackets
• Remove the outer film and the packaging.
• Flap open the transparent protective cover.
• Arrange the convector on the window side.
• Then level the trench heater and adjust the height using the adjustment
feet
1
with rubber pads for acoustic decoupling
2
and adjustment
screws on the raised floor brackets
3
with sound decoupling
4
.
• Use screws and dowels to fix the height-adjustment feet on the room
side with rubber pads.
4.2. Positioning and fixing at the installation site
Move the Katherm HK into its final installation position
1
. Pay attention
to the prescribed spacings to walls and façades
2
and
3
on site. Align
the Katherm HK into its final horizontal position (
4
,
5a
and
5b
) and
fix the Katherm HK for the floor with screws and rawlplugs (supplied by
others)
6
.
Arrangement of air outlet/convector
Katherm HK 320
with trench height
130 mm
window-side
arrangement
Katherm HK 290
with trench height
160 mm
window-side
arrangement
Katherm HK 360
with trench height
210 mm
window-side
arrangement
5
4
4
3
3
2
1
1
2
3
4
6
5b
5a
Expansion
joint on-site
On-site
Summary of Contents for Katherm HK Series