26
1.43
Katherm HK
Ready-to-install trench heaters with EC tangential fan
Assembly and installation instructions
* With Katherm HK 290, H = 160 mm or HK 360, H = 210 mm , the installation position of the
condensation tray and thus also the corresponding dimensions are identical to those of the Katherm HK
320, H = 130 mm. Only the dimensions of the trench height differ.
Step 4:
Fix a section of condensate hose
6
to the float module
with a cable tie provided. Use the coupling section
5
to connect the
condensation hose section to the condensation bend section
4
. You
will need cable ties to fix it in place. Then use the hose clamp to fix the
condensation bend section to the outlet connection of the condensation
tray
8
.
Step 5:
Please refer to the separate manufacturer's installation instructions
and the electrical wiring information for further steps to ensure the correct
installation of the condensate pump.
Window-side
Window-side
Window-side
Example shown: Katherm
HK 320, 4-pipe with
valves fitted
Example: Plan view of Katherm
HK 320 with condensation
pump fitting kit installed
Recommended order of assembly
1. Condensation pump fitting kit
2. Valves with actuator
Side view
Front view