LRWMANUAL 0918
KAM CONTROLS, INC.
4
S P E C I F I C AT I O N S
Media:
Crude oil and refined products
Wetted parts:
316 SS, hastelloy, & PEEK (Other materials available)
Fluid temp:
To 300º F (149º C)
Electronics temp:
-40º F to 158º F (-40º C to +70º C)
Power requirements:
24 VDC
Power consumption:
12 watts
Available ranges:
0-3%, 0-5%, 0-10% water in oil
Accuracy:
1% of range (0-10% models have an accuracy of 0,05% for water from 0-5% and an
accuracy of 0,1% for water from 5-10%)
Repeatability:
+/- 0.01%
Resolution:
+/- 0.01%
Minimum water detection: 300 ppm (0-3% models)
Outputs/serial ports:
4–20 mA
Alarm relay
RS232 ASCII (calibration and diagnostics only)
RS485 Modbus
Input:
4-20 mA for density
Density Correction:
AnyDensity
™
compensates for changes in fluid density across entire API gravity range
(requires density input)
Ingress protection:
NEMA IV; IP66
Temperature Correction: Automatic
Pressure ratings:
ANSI 150, 300, 600, 900
Flow conditions:
Well mixed in accordance with API MPMS Chapter 8.2 mixing requirements, vertical
installation strongly recommended
Enclosure hazardous
approvals:
Explosion-proof for Class I, Division 1, Groups B, C and D
Dust-ignition-proof for Class II/III, Division 1, Groups E, F and G,
hazardous (classified) locations, indoors and outdoors (Type 4X/IP66)
ATEX: II 2 G D, Ex d IIC, Ex tD A21, IP68, Ta = -40°C to +85°C
IEC EX: Ex d IIC, Ex A21 tD, IP68, Ta = -40°C to +85°C