M thermal Split
76
202004
Midea
M t
her
ma
l S
pli
t Ser
vice M
anual
4.17 P3 Troubleshooting
Digital display output
4.17.1
Description
4.17.2
Compressor current protection.
When the compressor current rises above the protection value (6kW models 18A, 8/10kW model 19A,
12/14/16kW single phase model 30A, 12/14/16kW three phase model 14A,), the system displays P3 protection and
Split stops running. When the current returns to the normal range, P3 is removed and normal operation resumes.
Error code is displayed on refrigerant system main PCB and user interface.
Possible causes
4.17.3
Poor condenser heat exchange.
High pressure side blockage.
Inverter module damaged.
Compressor damaged.
Outdoor unit main PCB damaged.
Midea CAC Confidential
M thermal Split
202004
77
Procedure
4.17.4
P3
No
The condenser heat exchange is poor
1
Yes
Inspect the system and fix the error
No
The high pressure side is blocked, caused
by crushed or bent pipe or blocked EXV
2
Yes
Inspect the system and fix the error
No
Inverter module has short-circuited
3
Yes
Replace the inverter module
No
Compressor has malfunctioned
4
Yes
Replace the compressor
No
Replace outdoor main PCB
Notes:
1. In heating mode check water side heat exchanger, water piping, circulator pumps and water flow switch for dirt/blockages. In cooling mode check air side
heat exchanger, fan and air outlets for dirt/blockages.
2. High pressure side blockage causes discharge temperature to be higher than normal, discharge pressure to be higher than normal and suction pressure to
be lower than normal.
3. Set a multi-meter to buzzer mode and test any two terminals of P N and U V W of the inverter module. If the buzzer sounds, the inverter module has
short-circuited.
4. The normal resistances of the inverter compressor are 0.7-1.5Ω among U V W and infinite between each of U V W and ground. If any of the resistances
differ from these specifications, the compressor has malfunctioned.
Midea CAC Confidential
Split
Summary of Contents for KMK-60RY1
Page 1: ...SERVICEMANUAL SPLIT TYPE HEAT PUMP R32...
Page 2: ...Split...
Page 4: ...M thermal Split 2 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 8: ...M thermal Split 6 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 18: ...M thermal Split Midea M thermal Split Service Manual 16 202004 Midea CAC Confidential Split...
Page 41: ...M thermal Split 202004 39 Midea CAC Confidential Split...
Page 42: ...M thermal Split 40 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 113: ...Split...
Page 114: ...kaisai com...