M thermal Split
84
202004
Midea
M t
her
ma
l S
pli
t Ser
vice M
anual
The specific error codes can also be obtained from the LED indicators on the inverter module.
Table 4-4.2: Errors indicated on LED, single-phase 4~10kW
LED301 flashing pattern (GREEN)
LED302 is always on (RED)
Corresponding error
Flashes 8 times and stops for 1 second, then repeats
L0 - Inverter module protection
Flashes 9 times and stops for 1 second, then repeats
L1 - DC bus low voltage protection
Flashes 10 times and stops for 1 second, then repeats
L2 - DC bus high voltage protection
Flashes 12 times and stops for 1 second, then repeats
L4 - MCE error
Flashes 13 times and stops for 1 second, then repeats
L5 - Zero speed protection
Flashes 16 times and stops for 1 second, then repeats
L8 - Compressor frequency variation greater than 15Hz within one second protection
Flashes 17 times and stops for 1 second, then repeats
L9 - Actual compressor frequency differs from target frequency by more than 15Hz
protection
Table 4-4.3: Errors indicated on LED, single-phase 4~10kW
LED1 flashing pattern (GREEN)
LED2 is always on (RED)
Corresponding error
Flashes 3 times and stops for 1 second, then repeats
P1 - High pressure protection
Flashes 5 times and stops for 1 second, then repeats
bH – PED board checking fail
Flashes 8 times and stops for 1 second, then repeats
L0 - Inverter module protection
Flashes 9 times and stops for 1 second, then repeats
L1 - DC bus low voltage protection
Flashes 10 times and stops for 1 second, then repeats
L2 - DC bus high voltage protection
Flashes 12 times and stops for 1 second, then repeats
L4 - MCE error
Flashes 13 times and stops for 1 second, then repeats
L5 - Zero speed protection
Flashes 16 times and stops for 1 second, then repeats
L8 - Compressor frequency variation greater than 15Hz within one second protection
Flashes 17 times and stops for 1 second, then repeats
L9 - Actual compressor frequency differs from target frequency by more than 15Hz
protection
Figure 4-4.1: LED location of inverter module
Inverter Module(
6
-10KW): LED301/302/303
Inverter Module(12-16KW): LED1/LED2/LED3
Midea CAC Confidential
Split
Summary of Contents for KMK-60RY1
Page 1: ...SERVICEMANUAL SPLIT TYPE HEAT PUMP R32...
Page 2: ...Split...
Page 4: ...M thermal Split 2 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 8: ...M thermal Split 6 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 18: ...M thermal Split Midea M thermal Split Service Manual 16 202004 Midea CAC Confidential Split...
Page 41: ...M thermal Split 202004 39 Midea CAC Confidential Split...
Page 42: ...M thermal Split 40 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 113: ...Split...
Page 114: ...kaisai com...