M thermal Split
58
202004
Midea
M t
her
ma
l S
pli
t Ser
vice M
anual
4.5 E3, E4, H2, H3, Ed, HA, H5, H9, Eb, E7,Ec Troubleshooting
Digital display output
4.5.1
Description
4.5.2
E3 indicates final outlet water temperature sensor error
E4 indicates a domestic hot water tank temperature sensor error.
H2 indicates a water side heat exchanger refrigerant outlet (liquid pipe) temperature sensor
error.
H3 indicates a water side heat exchanger refrigerant inlet (gas pipe) temperature sensor error.
Ed indicates a water side heat exchanger water inlet temperature sensor error.
HA indicates a water side heat exchanger water outlet temperature sensor error.
H5 indicates a room temperature sensor error.
H9
indicates a circuit 2 water outlet temperature sensor error.
Eb indicates solar panel temperature sensor error
E7 indicates balance tank upper temperature sensor error
Ec indicates
balance tank nether temperature sensor error
Split stops running.
Error code is displayed on hydronic box main PCB and user interface.
Possible causes
4.5.3
Temperature sensor not connected properly or has malfunctioned.
Damaged hydronic box main PCB.
Midea CAC Confidential
Split
Summary of Contents for KMK-60RY1
Page 1: ...SERVICEMANUAL SPLIT TYPE HEAT PUMP R32...
Page 2: ...Split...
Page 4: ...M thermal Split 2 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 8: ...M thermal Split 6 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 18: ...M thermal Split Midea M thermal Split Service Manual 16 202004 Midea CAC Confidential Split...
Page 41: ...M thermal Split 202004 39 Midea CAC Confidential Split...
Page 42: ...M thermal Split 40 202004 Midea M thermal Split Service Manual Midea CAC Confidential Split...
Page 113: ...Split...
Page 114: ...kaisai com...