Fig. 11 Topping up the compressor oil
1
Crankcase vent
1. Remove the crankcase vent from the oil filler.
2. Top up to bring the oil to the correct level.
3. Replace the crankcase vent.
4. Start the machine and check the oil level again after about 2 minutes, topping up again, if nec‐
essary.
5. Switch off the machine and check visually for leaks.
10.8 Changing the compressor oil
Change the initial charge of oil as specified in table 31 .
Always drain the oil completely from the compressor block.
Change the oil immediately if it becomes milky.
This indicates a high condensate content.
Contact KAESER Service if condensate is detected in the oil.
Material Compressor oil
Oil receptacle
Precondition Machine at operating temperature.
The supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
CAUTION
Danger of burning from hot components and scalding from escaping oil.
➤ Wear long-sleeved clothing and gloves.
10 Maintenance
10.8 Changing the compressor oil
No.: 9_9418 20E
Service Manual Reciprocating compressor
Premium compact W
39
Summary of Contents for Premium Compact W 200/4
Page 2: ...Original instructions KKW PPWCO 2 00 en SBA PREMIUM COMPACT TRAGBAR 20120822 115136 ...
Page 6: ...Contents iv Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...
Page 10: ...List of Tables viii Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...