The pressure gauge does not read 0 bar after venting?
Shut-off valve still open.
➤ Defective condensate drain.
➤ If manual venting does not bring the oil separator tank pressure gauge to zero: Contact
the authorised KAESER Service.
10.12 Maintaining the check valve
The check valve is installed in the air receiver inlet port. It prevents the compressed air from flow‐
ing back from the air receiver to the compressor block.
Material Compressed air for blowing out
Cleaning cloths
Spares as required
Precondition The supply disconnecting device is switched off.
The disconnecting device is locked off.
A check has been made that no voltage is present.
The machine is fully vented (no pressure). Verify the absence of pressure using a suitable measur‐
ing device (pressure gauge).
The machine has cooled down.
The user's shut-off valve between the machine and the air network is closed.
Fig. 16 Cleaning the check valve
1
Enclosure
2
Screw plug
3
Valve cone
4
Valve seat
5
Spring
6
O-ring
1. CAUTION!
Danger of burns from hot components!
➤ Wear long-sleeved clothing and gloves.
➤ Work carefully.
2. Remove the plug.
3. Clean the valve cone and seat.
The complete valve must be replaced if the valve seat is badly worn or damaged.
4. Insert the valve cone, spring and O-ring in the valve seat.
5. Close the check valve with screw plug and O-ring.
10 Maintenance
10.12 Maintaining the check valve
No.: 9_9418 20E
Service Manual Reciprocating compressor
Premium compact W
43
Summary of Contents for Premium Compact W 200/4
Page 2: ...Original instructions KKW PPWCO 2 00 en SBA PREMIUM COMPACT TRAGBAR 20120822 115136 ...
Page 6: ...Contents iv Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...
Page 10: ...List of Tables viii Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...