Rated power supply: 115V±5%/1/60Hz
Premium compact
Mains fusing [A]
Supply cable [mm
2
]
Current consumption
[A]
160/4
—
—
—
200/4
—
—
—
250/4
25
3 x 4
15.6
Tab. 17 Mains supply 115V/1/60Hz
Rated power supply: 127V±5%/1/60Hz
Premium compact
Mains fusing [A]
Supply cable [mm
2
]
Current consumption
[A]
160/4
16
3 x 1.5
11.3
200/4
16
3 x 1.5
11.3
250/4
—
—
—
300/4
—
—
—
Tab. 18 Mains supply 127V/1/60Hz
Rated power supply: 220V±5%/1/60Hz
Premium compact
Mains fusing [A]
Supply cable [mm
2
]
Current consumption
[A]
160/4
10
3 x 1.5
6.5
200/4
10
3 x 1.5
6.5
250/4
—
—
—
300/4
—
—
—
Tab. 19 Mains supply 220V/1/60Hz
Rated power supply: 230V±5%/1/60Hz
Premium compact
Mains fusing [A]
Supply cable [mm
2
]
Current consumption
[A]
160/4
—
—
—
200/4
—
—
—
250/4
16
3 x 1.5
7.8
300/4
20
3 x 2.5
11.2
Tab. 20 Mains supply 230V/1/60Hz
2.11 Mains conditions
The machines listed in the table below are intended for use in changing locations.
2
Technical Specifications
2.11 Mains conditions
No.: 9_9418 20E
Service Manual Reciprocating compressor
Premium compact W
9
Summary of Contents for Premium Compact W 200/4
Page 2: ...Original instructions KKW PPWCO 2 00 en SBA PREMIUM COMPACT TRAGBAR 20120822 115136 ...
Page 6: ...Contents iv Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...
Page 10: ...List of Tables viii Service Manual Reciprocating compressor Premium compact W No 9_9418 20E ...