No interference with other devices is to be expected with network impedance less than Z
max
[Ohm]. In general, the maximum permissible network impedance will not be exceeded if the ma‐
chine is supplied at the transfer point with a rated current of I
equiv
.
2.11.1 Mains conditions at 230V/1/50Hz
Premium compact
Max. permissible mo‐
tor starts [1/h]*
Highest permissible
system impe‐
dance Z
max
[Ω]**
Rated current
I
equiv.
[A]
160/4
20
0.244
32
200/4
20
0.244
32
250/4
20
0.292
32
300/4
20
0.112
80
* For exceeding the maximum permissible motor starts, please consult the manufacturer.
** Specification related to the sum of impedances in external and neutral lines.
Tab. 21 Network impedance
2.12 Machine duty cycle
Calculating the cycling period
Cycling time = time under load + time at standstill
Calculating the duty cycle:
Duty cycle [%] =
time under load
time under load + standstill time
x 100
Example:
12 minutes
20 minutes
x 100 % = 60 %
The following values are valid for:
■ 20 °C ambient temperature
■ 30 % relative humidity
■ 1013 mbar air pressure
Premium compact
Duty cycle [%]
Cycle time [min]
160/4
≤ 70
3–20
200/4
≤ 70
3–20
250/4
≤ 70
3–20
300/4
≤ 70
3–20
Tab. 22 Machine duty cycle
2
Technical Specifications
2.12 Machine duty cycle
10
Service Manual Reciprocating compressor
Premium compact W
No.: 9_9418 20E