Fig. 14 Draining condensate
1
Condensate drain tap
➤ Drain the condensate out daily.
Drain the condensate into a suitable receptacle and dispose of according to environmental
regulations.
10.11 Venting the machine (de-pressurising)
Even when switched off the machine is still under pressure from the air network back to the check
valve.
The machine must be isolated from the air network and completely vented before undertaking
any maintenance or service work on the pressure system.
Precondition The supply disconnecting device is switched off.
The disconnecting device is locked off.
A check has been made that no voltage is present.
The machine has cooled down.
Fig. 15 Venting the machine
1
Condensate drain tap
1. DANGER!
Compressed air!
Compressed air and devices under pressure can injure or cause death if the contained energy
is released suddenly.
➤ Isolate the compressor from the air system.
2. Open the condensate outlet slowly to release pressure.
3. Check that the air receiver pressure gauge reads 0 bar.
10 Maintenance
10.11 Venting the machine (de-pressurising)
42
Service Manual Reciprocating compressor
Premium compact W
No.: 9_9418 20E