background image

40L 1.8HP OiL Free Direct Drive

UPrigHt Air cOmPressOr

OPerAtOr's mANUAL

OrigiNAL iNstrUctiONs

rA-AcDDU1840

1

Important!

 

   

  

It is essential you read the instructions in this manual before starting and 

operating this machine. 

 

Subject to technical modifications.

Summary of Contents for RA-ACDDU1840

Page 1: ...Drive Upright Air Compressor Operator s MANUAL Original instructions RA ACDDU1840 1 Important It is essential you read the instructions in this manual before starting and operating this machine Subject to technical modifications ...

Page 2: ...ssure gauge 7 Pressure regulator knob 8 Wheel 9 Air filter assembly 10 Reset button 11 Air tank 12 Rubber foot 13 Hex nut 14 Flat washer 15 Bolt 16 Axle bolt 17 Wheel axle cover 18 To close 19 Quick connect air fitting 20 Quick coupler 21 On 22 Off 23 To open 24 Drain valve lever 25 Air filter housing 26 Air filter 27 Air filter cover 28 Wing nut ...

Page 3: ...Fig 2 Fig 3 12 14 15 13 14 Fig 3 Fig 4 Fig 6 Fig 5 14 14 13 17 16 1 8 9 11 8 12 9 10 ...

Page 4: ...Fig 7 Fig 9 Fig 10 Fig 11 Fig 14 Fig 12 Fig 8 3 19 22 10 6 2 23 20 21 19 4 24 Fig 13 26 25 28 27 14 18 ...

Page 5: ... operation is dusty Protect your hearing Wear hearing protection during extended periods of operation Do not overreach Keep proper footing and balance at all times Remove adjusting keys and wrenches Form habit of checking to see that keys and adjusting wrenches are removed from tool before turning it on Air compressor use and care Do not exceed the pressure rating of any component in the system Pr...

Page 6: ...nimals Take care not to blow dust and dirt towards yourself or others Following this rule will reduce the risk of serious injury Do not use this air compressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint Do not carry while painting Inspect product cords and hoses periodically and if damaged have the...

Page 7: ...lready assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have care...

Page 8: ...ed make sure the power cord is secured in the cord wrap To move the air compressor 1 Grasp the handle firmly 2 Tilt the air compressor toward you Make sure the compressor is balanced on the wheels 3 Pull the compressor along to the desired location 4 Recover the air compressor to its upright position until it sits securely on a flat surface ATTACHING DISCONNECTING Air HOSE See figure 7 NOTE For op...

Page 9: ...ill drain air from the tank more rapidly and cause the unit to cycle on more frequently 10 When finished always drain the tank and unplug the unit Never leave the unit plugged in and or running unattended 11 It is recommended to use a residual current device with a rated residual current of 30 mA or less DRAINING THE TANK See figure 12 13 To prevent tank corrosion and keep moisture out of the air ...

Page 10: ...nected to air hose may operate accidentally causing serious personal injury WARNING Failure to unplug the air compressor before storage may result in the compressor running continuously causing overheating damage to the compressor and possibly a fire MAINTENANCE WARNING When servicing use only original replacement parts Use of any other parts may create a hazard or cause product damage WARNING Alw...

Page 11: ...aution risk of electric shock Wet condition alert Do not expose to rain Store indoors Risk of bursting Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment Do not use at pressure greater than 8 bar Risk of fire or explosion Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as f...

Page 12: ...ire and cord length Shorted or open motor winding Take compressor to service centre Defective check valve or unloader Take compressor to service centre Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire an...

Page 13: ...Take compressor to service centre Decrease air usage compressor not large enough for tool s requirement Piston rings are worn Replace piston rings air inlet filter is blocked call customer service for assistance Air output lower than normal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections 20150113v1 ...

Page 14: ...10 Parts list 55 56 57 58 57 34 32 59 52 51 49 50 ...

Page 15: ... 6 28 Rear cap HT200 48 Drain cock 09 Bolt M6 x 15 LH 29 Bolt M5 x 140 49 Nut M10 10 Piston pin YL104 30 Spring washer 5 50 Washer 10 11 Leather bowl 31 Washer 5 51 Wheel 12 Connecting rod cover YL104 32 Motor left housing PP 52 Bolt M10 x 75 13 Bolt M6 x 16 33 Bolt M5 x 20 53 Bolt M5 x 18 14 Cylinder 63 34 Motor right housing PP 54 Panel 15 Gasket XB150 35 Pressure switch 55 Panel Support 16 Valv...

Page 16: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...

Reviews: