Switching the machine to the run-on phase
➤ Switch the machine to the run-on phase.
■ ➤ Press «LOAD/IDLE» key.
■ The machine switches to
unloaded run-on.
─ The engine runs at IDLE speed.
─ Oil separator tank (OST) is vented.
─ The inlet valve closes.
■
0.5 - 3 minutes ( engine can be switched off).
■ ➤ Press and hold the «STOP» key for more than 1 second.
■ The engine switches off.
Stopping the drive engine
➤ Turn the engine off after the cooling-down phase.
■ ➤ Press and hold the «STOP» key for more than 1 second.
■ The machine switches to
unloaded run-on.
─ The engine runs at IDLE speed
─ Oil separator tank (OST) is vented.
─ The inlet valve closes.
─ The engine switches off, controlled by a timer.
■ The controller display shows
back pressure if the pressure in the oil separator tank is still
> 14.5 psi.
■ When the machine is fully vented, the display changes to
Ready to start.
■ When the OST is fully vented after shut down, the re-start inhibitor is activated and is in‐
dicated by the timer counting down from 20 seconds.
Shutting down the controller
1.
Memory fault!
Damage to the machine electronics and/or controller is possible.
➤ Shut down the controller only after the engine control unit has completed its save process.
2. Shut down the controller.
■ ➤ Switch off the «controller ON/OFF» key.
Shutting down the machine
1. Switch off the «controller ON/OFF» switch.
2. Close all «compressed air outlet valves» on the air outlet.
3. Close the control panel cover.
4. Close both doors.
8.2.9 Shutting down in an emergency
In the event of danger, shut the machine down immediately by activating the
«EMERGENCY STOP» push button.
8
Operation
8.2
Starting up and shutting down
No.: 902366 10 USE
Operator Manual Portable Rotary Screw Compressor
MOBILAIR M55 PE SIGMA CONTROL SMART pV