4. Remove the strainer.
5. Clean the male stud fitting, nozzle and strainer with cleaning solvent or spirit.
6. Check the nozzle and strainer for wear.
When severely worn: replace components.
7. Install the nozzle and strainer in/on the male stud fitting.
8. Install male stud fitting by using the correct angular adjustment (see Fig. 57).
Fig. 57 Install the male stud fitting
1
Control valve
2
Male stud fitting
3
Angle bracket
9. Install the oil return line clamping nut.
10.6.5.3 Preparing for operation
1. Connect the negative battery terminal.
2. Switch on the «Controller ON/OFF» switch.
3. Close the door.
10.6.5.4 Starting the machine and performing a test run
1. Switch on machine by using the «START» key on the control panel of
SIGMA CONTROL SMART.
2. Warm-up machine by letting it run in IDLE mode.
Warm-up has been successful when required airend discharge temperature has been reached.
3. Press and hold the «OFF» key on the control panel of SIGMA CONTROL SMART for more
than 1 second.
The machine is switched off.
4. Wait until the machine has automatically vented.
Pressure gauge reads 0 psig!
5. Open the outlet valves.
6. Open the left-hand door.
7. Visually inspect for leaks.
8. Close the door.