Starting the machine and performing a test run:
1. Switch on the machine using the «START» key on the control panel of the
SIGMA CONTROL SMART.
2. Warm-up the machine by allowing it to run in IDLE.
Warm-up has been achieved when the required airend discharge temperature is reached.
3. Press and hold down the «OFF» key on the control panel of the SIGMA CONTROL SMART for
longer than 1 second.
The machine shuts down.
4. Wait until the machine has automatically vented.
The pressure gauge reads 0 psig!
5. Open the discharge valves.
Checking the filter combination for leaks:
1. Open the door/s.
2. Visually inspect the filter combination for leaks.
3. Visually inspect the condensate hose lines for leaks.
4. Close the door/s.