Displaying the firmware version
F
Open the Information / SW version menu.
ð
The device will display the versions and checksums of the software that is currently loaded.
9.7
Access via Modbus
NOTE
In order to make use of the Modbus functionality, we recommend using the “SunSpec-Modbus-Interface” spe-
cification we have made available for the firmware version installed on your device.
Follow the description in the document “Modbus-Protokol.pdf” in order to use the two Excel files with a high
level of process reliability.
↻
Firmware version of device is identical to the specifications of the Sunspec® Modbus®.
1. Enable the entry
Network – Modbus TCP - Operation mode
/
Network services – Modbus
TCP
- Operation mode
in the menu on the device or on the web interface.
2. If necessary, allow
write access
.
3. Set up the
Port
for access. [Default:
502
]
ð
Access via Modbus enabled.
9 | Configuration and operation
Manual
KACO blueplanet 15.0TL3 KACO blueplanet 20.0TL3
Page 56
EN
Summary of Contents for blueplanet 15.0 TL3
Page 95: ......