Getting Started
12
Power Switch
Switches the power on or off. The OPERATE ON mode is
automatically activated when the power is switched on.
(Page 16)
*
Make sure the system has been set in the OPERATE
OFF mode before switching off the power supply.
[AC IN(220V - 240V)] Power Input Terminal
Connect using the power cable supplied to an AC 220 -
240 V outlet. (Page 16)
[VIDEO OUT] Terminal (BNC)
This function is the same as the
[VIDEO OUT] terminal
on the front panel.
[SPOT OUT] Terminal (BNC)
Outputs live images screens. Also enables different
contents from the [VIDEO OUT] to be output. (Page 26)
[VIDEO IN] Camera Image Signal Input (BNC)
Connect this to the video output of the video camera (sold
separately).
[THRU OUT] Camera Image Output Terminal (BNC)
Output camera image signals that support the various
[VIDEO IN] terminals. Also enables monitor televisions to
be connected (automatic terminals).
[AUDIO IN] Terminals 1 and 2 (RCA)
Connect this to the audio output terminal of the device from
which audio signals are to be recorded.
[AUDIO OUT] Terminal (RCA)
This function is the same as the
[AUDIO OUT] terminal
on the front panel.
[VGA OUT] VGA Output Terminal (D-SUB 15 PIN)
Outputs live images, playback images and the menu
screens. Outputs the same contents as [VIDEO OUT].
(Page 24)
[LAN] Connection Interface (100 Base-T)
For connection to the Intranet and other networks using a
LAN cable. (Page 65)
[RS-232C] Remote Terminal (D-sub 9 PIN)
Enables the VR-509 to be controlled from an external
source when connected to a personal computer or other
device.
*
See page 116 for details on the RS-232C interface.
[SERIAL] Serial Terminal (USB A-TYPE Female)
Used to connect the flash memories (sold separately),
additional hard disk drives (sold separately), (Page 114)
and the communication control terminals on UPS (sold
separately).
This port has the same function as the
SERIAL port on
the front panel.
Signal Input/Output Terminal
For operating VR-509 using external alarm signals or
signals received from external devices, or for operating
external devices by outputting signals. (Page 13)
*
Diameter of applicable cables:
φ
0.3mm to
φ
0.8mm (AWG 22 to 28.)
(If separate wires are used, twist them together and
solder them.)
Part Names and Functions (Rear Panel)
AC IN 220V - 240V
50Hz/60Hz
WARNING:
SHOCK HAZARD
-DO NOT OPEN
AVIS:
RISQUE DE CHOC ELECTRIQUE-NE
PAS OUVRIR
23
22
20
21
24
28
29
30
31
32
27
25
26
20
21
22
3
23
24
25
26
27
3
28
29
30
31
4
32