Explanations
106
There are 3 types of Skip Jump, namely “TIME”, “ALARM” and
“EVENT”, which can be specified in the search menu. Display
the [SKIP SET] menu screen to execute Skip Jump setting.
(Page 44)
When “TIME” is selected
• Selecting “1HOUR” for Time Jump Setting enables
jumps in 1 hour intervals every time the [SKIP] button is
pressed. Jumps to the closest position from the specified
time onwards if the time to jump to is not found.
When “ALARM” is selected
• Pressing [SKIP] each time enables a jump to the start
position of alarm or sensor recording.
• The display will jump to the starting position of the pre-
alarm recording when pre-alarm recordings exist.
When “EVENT” is selected
• Pressing [SKIP] each time enables a jump to the start
position of recording (start of an event).
If the [SKIP] button is pressed during playback with the [SKIP
PLAY] setting on the [SKIP PLAY] menu temporarily set to “10
SEC”, the playback and skip operations will be repeated at
intervals of ten seconds until no more relevant recorded images
can be found.
Skip jump
SKIP SET
SKIP PLAY
SKIP MODE
TIME JUMP
OFF
TIME
5MIN
Set
Event1
Event2
Event3
10:30
Record
12:00
Stop
12:15
Record
13:00
Stop
15:00
Record
1HOUR
1HOUR
11:30
12:30
15:00
10:30
Event1
Event2
(Alarm1)
Event3
Prealarm
Event4
(Alarm2)
SKIP PLAY
Event1
Event2
(Alarm1)
Event3
Prealarm
Event4
(Alarm2)
Event 1
Event 2
10 sec.