Media Flow Controller CLI Commands
Media Flow Controller Administrator’s Guide
358
stats
Copyright © 2010, Juniper Networks, Inc.
show ssh server [host-keys]
SSH server information, including whether or not it is enabled, and the host key fingerprints.
Use the host-keys option to list information about the SSH server, including whether or not it
is enabled, the host key fingerprints, and the full host keys.
stats
Configure statistics and alarms. To see default threshold values, enter show stats alarm
<alarm_ID>. Set email notifications for these stats using
commands. See
“Configuring
Log Statistics Thresholds (CLI)” on page 231
for task details.
stats
alarm <alarm_ID>
clear
enable
falling [clear-threshold <value>] [error-threshold <value>]
rate-limit
count {long <count> | medium <count> | short <count>}
reset
window {long<duration> | medium<duration> | short<duration>}
rising [clear-threshold <value>] [error-threshold <value>]
chd <CHD_ID>
clear
compute time [interval <seconds>] [range <seconds>]
enable
clear-all
export {<format> | csv} {<report_name>| cpu_util | memory | paging}
after <date><time> [before <date><time>]
before <date><time> [after <date><time>]
filename <filename>
after <date><time> [before <date><time>]
before <date><time> [after <date><time>]
sample <sample_ID>
clear
enable
interval <number_of_seconds>
Notes:
•
alarm <alarm_ID>
—Configure alarms based on sampled or computed statistics. See
“stats alarms,"
for the list of supported alarms. Some statistics are of concern when they
fall below a certain point, others when they rise above a certain point.
•
clear
—Clear all state for this alarm. Clearing an alarm resets it to a nonerror state,
clears the watermarks, and forgets the event history.
Note!
“watermark” for rising
alarm = max value since reset; for falling alarm = min value since reset.
•
enable
—Enable this alarm. Use no stats alarm <alarm_ID> enable to disable.
•
falling
—Set alarm for when specified statistic fall too low.
•
clear-threshold <value>
—This value terminates the alarm.
•
error-threshold <value>
—This value initiates the alarm.
•
rate-limit
—Set alarm event rate-limits:
Summary of Contents for MEDIA FLOW CONTROLLER 2.0.4 -
Page 6: ...Media Flow Controller Administrator s Guide VI Copyright 2010 Juniper Networks Inc...
Page 24: ...LIST OF FIGURES XXIV Copyright 2010 Juniper Networks Inc...
Page 37: ...Copyright 2010 Juniper Networks Inc 37 PART 1 Media Flow Controller Administration...
Page 38: ...Media Flow Controller Administrator s Guide 38 Copyright 2010 Juniper Networks Inc...
Page 285: ...Copyright 2010 Juniper Networks Inc 285 PART 2 Media Flow Controller Command and MIB Reference...
Page 286: ...Media Flow Controller Administrator s Guide 286 Copyright 2010 Juniper Networks Inc...