Current state Backup
Election priority Backup (default)
Temperature 36 degrees C / 96 degrees F
DRAM 768 MB
Memory utilization 16 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model RE-2.0
Serial ID 6d000007c8150801
Start time 2003-04-22 10:01:29 PDT
Uptime 16 days, 3 hours, 6 minutes, 34 seconds
•
Issue the CLI
show chassis environment mcs
command to check the status of the MCSs.
As shown in the sample output, the MCS that belongs to the master host module is
designated
Master
in the
State
field:
user@host>
show chassis environment mcs
MCS 0 status:
State Online Master
Temperature 48 degrees C / 118 degrees F
Power:
3.3 V 3299 mV
5.0 V 4971 mV
12.0 V 11770 mV
5.0 V bias 4989 mV
8.0 V bias 8246 mV
BUS Revision 12
FPGA Revision 13
MCS 1 status:
State Online Standby
Temperature 51 degrees C / 123 degrees F
Power:
3.3V 3316 mV
5.0 V 5001 mV
12.0 V 11775 mV
5.0 V bias 5001 mV
8.0 V bias 8249 mV
BUS Revision 12
FPGA Revision 13
For further description of the output from the commands, see the
Junos OS System Basics
and Services Command Reference
.
Related
Documentation
M40e Host Module Description on page 23
•
•
Host Module LEDs on the M40e Craft Interface on page 37
Maintaining M40e FPCs
Purpose
Verify the condition of the FPCs.