Figure 66: Routing Engine Management Ports and Alarm Relay Contacts
Connecting the M40e Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet cable with RJ-45 connectors to the
ETHERNET
port on the CIP. One such cable
is provided with the router. For cable specifications, see “Routing Engine Interface Cable
and Wire Specifications for the M40e Router” on page 288. To connect the Routing Engine
to a network for out-of-band management:
1.
Turn off the power to the management device.
2.
Plug one end of the Ethernet cable (Figure 67 on page 115 shows the connector) into
the appropriate
ETHERNET
port on the CIP. Figure 68 on page 115 shows the external
device ports on the CIP. The ports labeled
HOST 0
connect to the Routing Engine in
the upper Routing Engine slot (
RE 0
), and the ports labeled
HOST 1
connect to the
Routing Engine in the lower Routing Engine slot (
RE 1
).
3.
Plug the other end of the cable into the network device.
Copyright © 2010, Juniper Networks, Inc.
114
M40e Multiservice Edge Router Hardware Guide