4.3.6 Setting operating mode and basic brightness
All our LB Management dimmers measure the characteristic of the connected load automatical-
ly and then select the best suitable dimming principle themselves.
For capacitive and ohmic loads,trailing edge phase control is usually set; for inductive loads
leading edge phase control.
Using the operating mode selection button, the dimming principle and the basic brightness can
also be specified manually during start-up. Thereby, an LED in the insert signals the current selec-
tion.
Universal
Trailing edge phase
control LED
Leading edge phase
control LED
Button
for setting
operating mode and
minimum brightness
ROTARY DIMMER
UNIVERSAL 1731 DD
TOUCH DIMMER
UNIVERSAL 1711 DE
STANDARD 1710 DE
L
1
N
Universal
Trailing edge phase
control LED
Leading edge phase
control LED
Button
for setting
operating mode and
minimum brightness
MINI UNIVERSAL DIMMER LED
1724 DM
LED lights green
− Automatic calibration to the load
− Trailing edge phase control for incandescent lamps, dimmable HV LED or compact fluores-
cent lamps as well as dimmable electronic transformers with LV halogen or LV LED lamps
− Leading edge phase control for dimmable inductive transformers with halogen or dimmable
LED lamps
− LED leading edge phase control for dimmable HV LED or compact fluorescent lamps
LED lights red
− The dimmer operates according to the trailing edge phase control principle
− Setting for incandescent lamps, HV halogen lamps, dimmable HV LED or compact fluorescent
lamps that can be dimmed according to the trailing edge phase control principle
− Dimmable electronic transformers with halogen or LED lamps
LED lights blue
− The dimmer operates according to the leading edge phase control principle
− Setting for incandescent lamps, HV halogen lamps, dimmable HV LED or compact fluorescent
lamps that can be dimmed according to the leading edge phase control principle
− Dimmable electronic transformers with halogen or LED lamps
LB MANAGEMENT LIGHT 93
Summary of Contents for LB management
Page 1: ...21 LB Management...
Page 2: ...Company founder Albrecht Jung Ernst Paris 2 COMPANY...
Page 4: ...4 PREFACE...
Page 9: ...THE JUNG LB MANAGEMENT 9...
Page 11: ...THE JUNG LB MANAGEMENT 11...
Page 15: ...THE JUNG LB MANAGEMENT 15...
Page 17: ...THE JUNG LB MANAGEMENT 17...
Page 31: ...Casa Fonte Boa Portugal Photos Jose Campos USAGE SCENARIOS 31 USAGE SCENARIOS 31...
Page 33: ...01 04 04 04 01 02 03 USAGE SCENARIOS 33...
Page 43: ...EQUIPMENT OVERVIEW 43...
Page 51: ...LB MANAGEMENT LIGHT 51...
Page 111: ...LB MANAGEMENT SHADING 111...
Page 139: ...TEMPERATURE CONTROL 139...
Page 155: ...THE CLEVER CONFIG APP 155...
Page 173: ...OPERATION 173...