![Jung LB management Manual Download Page 63](http://html1.mh-extra.com/html/jung/lb-management/lb-management_manual_2031681063.webp)
Standard rotary dimmer LED
You switch and dim the LEDs using the Standard Rotary Dimmer
LED. The switching on is performed by soft start that is gentle
on the lamp, and the operation of the device is also possible
without a neutral conductor. The standard rotary dimmer is
mounted in device sockets according to DIN 49073 with an
appropriate cover.
Overview of the functions:
− The device uses the leading edge phase control or trailing edge phase control principle
− The appropriate dimming principle for the load is set automatically or manually
− Switching on with the last set brightness or with the saved switch-on brightness
− Switch-on and minimum brightness can be saved permanently
− Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
− Capacity expansion possible using power boosters.
− Load:
− 20 – 210 W ohmic-capacitive
− capacitive-inductive: not permitted
− 20 – 210 VA ohmic-inductive
− 3 – 60 W ohmic and HV LED
− 3 – 60 W ohmic and compact fluorescent lamp
− 3 – 60 W dimmable electronic transformers with 12 V LED
− 3 – 60 W HV LED lamps
− Device can be operated without neutral conductor
− 230 V AC, 50/60 Hz
− Screw terminals
LB MANAGEMENT LIGHT 63
Summary of Contents for LB management
Page 1: ...21 LB Management...
Page 2: ...Company founder Albrecht Jung Ernst Paris 2 COMPANY...
Page 4: ...4 PREFACE...
Page 9: ...THE JUNG LB MANAGEMENT 9...
Page 11: ...THE JUNG LB MANAGEMENT 11...
Page 15: ...THE JUNG LB MANAGEMENT 15...
Page 17: ...THE JUNG LB MANAGEMENT 17...
Page 31: ...Casa Fonte Boa Portugal Photos Jose Campos USAGE SCENARIOS 31 USAGE SCENARIOS 31...
Page 33: ...01 04 04 04 01 02 03 USAGE SCENARIOS 33...
Page 43: ...EQUIPMENT OVERVIEW 43...
Page 51: ...LB MANAGEMENT LIGHT 51...
Page 111: ...LB MANAGEMENT SHADING 111...
Page 139: ...TEMPERATURE CONTROL 139...
Page 155: ...THE CLEVER CONFIG APP 155...
Page 173: ...OPERATION 173...