background image

21

LB

 

Management

Summary of Contents for LB management

Page 1: ...21 LB Management...

Page 2: ...Company founder Albrecht Jung Ernst Paris 2 COMPANY...

Page 3: ...ude the commitment to con stant new thinking A commitment to the development of ideas that create something new for easier use better func tionality more attractive appearance and more customer friend...

Page 4: ...4 PREFACE...

Page 5: ...able secure and energy effi cient with the new LB Management system A comprehensive range of products that can be individually combined accord ing to a modular principle makes possible the control of...

Page 6: ...RVIEW 44 3 1 Inserts 45 3 2 Attachments 45 3 3 Combination Possibilities 46 3 4 Satellite Units 48 3 5 Mix up Protection 48 3 6 Backwards Compatibility 49 4 LB MANAGEMENT LIGHT 52 4 1 Equipment Overvi...

Page 7: ...4 6 Change temperature parameters 152 6 4 7 Change parameters for control 152 6 4 8 Display setpoint and actual temperature or current time 153 7 THE CLEVER CONFIG APP 156 7 1 Operation made easy 157...

Page 8: ...The JUNG LB Management 1 1 Easy to install 12 1 2 Intuitive operation 14 1 3 Clear advantages 16 8 THE JUNG LB MANAGEMENT...

Page 9: ...THE JUNG LB MANAGEMENT 9...

Page 10: ...almost every desired function It is possible to control the LB Manage ment manually on the device automatically using sensors and or timers and using the JUNG smart phone app The easy to install inse...

Page 11: ...THE JUNG LB MANAGEMENT 11...

Page 12: ...easy and quick installation and ensure a secure hold in the flush mounted box and cavity wall box 1 2 1 2 The new inserts enable checking of the installation using the test button 1 also without attac...

Page 13: ...as been plugged in to the wrong insert e g after a renovation 1 2 The mounting of the frames and attachments is particularly easy thanks to stable supporting plates and retaining springs made of stain...

Page 14: ...ation In addition to the manual operation the Bluetooth compo nents of the new LB Management system are conveniently operated and configured using a smart phone with the JUNG Clever Config App 14 THE...

Page 15: ...THE JUNG LB MANAGEMENT 15...

Page 16: ...AND MODERNISERS Components for different applications switching dimming roller shutters blinds etc Simple and intuitive operation for all age groups Optionally control using Clever Config App is poss...

Page 17: ...THE JUNG LB MANAGEMENT 17...

Page 18: ...03 Alarm function 02 03 07 Light and automatic ventilation for the guest toilet 04 08 Temperature control in the bath room 05 Convenient lighting control with satellite units 06 08 04 06 07 06 10 11 2...

Page 19: ...satellite units and 2 gang touch dimmer 07 Automatic shading in the case of strong sunlight 08 Shade complete areas using group control 09 Automatic shading control with Lock out protection 10 Presen...

Page 20: ...ness The light stays off if there is sufficient daylight It s that simple COMPONENTS REF NO QUANTITY DETAILS Relay switch insert 1 channel 1701 SE 1 see page 53 3 wire satellite unit 1723 NE 1 see pag...

Page 21: ...ere with up to 10 satellites COMPONENTS REF NO QUANTITY DETAILS Relay switch insert 1 channel 1701 SE 1 see page 53 3 wire satellite unit 1723 NE 1 see page 66 Standard automatic switch 1 1 m 17180 1...

Page 22: ...io also plays music This is not a problem with the JUNG Smart Radio The movement detector switches off lighting and radio again automatically if movement is no longer detected COMPONENTS REF NO QUANTI...

Page 23: ...es on three minutes after switching off the lighting The programmable shut off delay ensures the best possible air circulation COMPONENTS REF NO QUANTITY DETAILS Relay switch insert 2 channel 1702 SE...

Page 24: ...tection function and valve protection are of course included COMPONENTS REF NO QUANTITY DETAILS Relay switch insert 2 channel 1702 SE 1 see page 54 Standard centre plate 1700 1 see page 74 Room thermo...

Page 25: ...ting can be dimmed with the Universal Touch Dimmer as master unit Also using the satellite units COMPONENTS REF NO QUANTITY DETAILS Universal touch dimmer 1711 DE 1 see page 58 2 wire satellite unit 1...

Page 26: ...er as master unit Also via the satellite units and separately for each luminaire if a 2 gang touch dimmer is used COMPONENTS REF NO QUANTITY DETAILS 2 gang touch dimmer Universal LED 1712 DE 1 see pag...

Page 27: ...can be suppressed using a Universal centre plate Furthermore a memory function enables two additional movement times for the connected motors COMPONENTS REF NO QUANTITY DETAILS Universal blinds inser...

Page 28: ...d brightness is exceeded the shading moves down to protect the room against overheating and strong ultraviolet radiation The brightness threshold the shading position and the schedule can be set indiv...

Page 29: ...tically while there is still somebody present outdoors You activate the lock out preven tion simply by pressing a button on the Universal centre plate COMPONENTS REF NO QUANTITY DETAILS Universal blin...

Page 30: ...on or the delay time is extended The auto matic shading control can also be automated easily using the Clever Config app so that nobody has to look after the house during your holiday COMPONENTS REF...

Page 31: ...Casa Fonte Boa Portugal Photos Jose Campos USAGE SCENARIOS 31 USAGE SCENARIOS 31...

Page 32: ...in the entrance area Lighting and shade as required in the meeting room Automatic staircase light conversion Individual presence detector with constant light function Semi automatic lighting with ene...

Page 33: ...01 04 04 04 01 02 03 USAGE SCENARIOS 33...

Page 34: ...light again to CONTINUOUS ON with a brightness of 80 percent from 16 00 to 18 00 After the end of work starting from 18 00 the base brightness is switched off and the lighting is only switched on if...

Page 35: ...he implementation and energy costs during operation Illuminated or non illuminated buttons can be installed in combination with the automatic switches as required COMPONENTS REF NO QUANTITY DETAILS Pu...

Page 36: ...a meeting Based on this the lighting intensity adapts itself to the actual light requirement When the meeting is finished the lighting is completely switched off after a specified delay time COMPONENT...

Page 37: ...nstant light control If an office is not occupied the lighting is also switched off The desired brightness and other settings can be adjusted individually using the JUNG Clever Config app Comfortably...

Page 38: ...ice kitchens server rooms WC or copier room The lighting is switched on with the Standard centre plate and optionally switches off automatically after five ten or 30 minutes The functions can be conve...

Page 39: ...ed depending on movement via the automatic switch With the lock function of the Universal centre plate you deactivate both the automatic as well as the memory functions and as a result can control the...

Page 40: ...lighting up to 800 W The standardised brightness of the entire lighting installation provides a harmonious well being ambiance COMPONENTS REF NO QUANTITY DETAILS Universal LED dimmer for rail mountin...

Page 41: ...he detection area of the ceiling observer as well as the delay time and switch on brightness can be comfortably adjusted using the Clever Config app Once you have optimally parametrised a device you c...

Page 42: ...Equipment Overview 3 1 Inserts 45 3 2 Attachments 45 3 3 Combination Possibilities 46 3 4 Satellite Units 48 3 5 Mix up Protection 48 3 6 Backwards Compatibility 49 42 EQUIPMENT OVERVIEW...

Page 43: ...EQUIPMENT OVERVIEW 43...

Page 44: ...erview Completely in accordance with the modular principle the LB Management system provides different inserts and attachments that can be combined for individual control of lighting and shade 44 EQUI...

Page 45: ...otary dimmer LED 1731 DD 3 wire rotary satellite unit 1733 DNE Universal LED dimmer for rail mounting UD 1755 REG LED power booster for rail mounting ULZ 1755 REG Room thermostat insert with sensor co...

Page 46: ...BLINDS INSERT RELAY SWITCH INSERT 1 CHANNEL ELECTRONIC SWITCH INSERT 1 CHANNEL STANDARD TOUCH DIMMER LED UNIVERSAL TOUCH DIMMER LED POWER DALI PUSH BUTTON CONTROLLER TW 2 WIRE SATELLITE UNIT 3 WIRE SA...

Page 47: ...MATIC SWITCH 1 1M BLINDS INSERT AUTOMATIC SWITCH 2 2 M BLINDS INSERT AUTOMATIC SWITCH 1 1M UNIVERSAL AUTOMATIC SWITCH 2 2 M UNIVERSAL CEILING OBSERVER PRESENCE DETECTOR STANDARD ROOM THERMOSTAT WITH D...

Page 48: ...ple for renovation of the inserts The following rules apply so that the attachments can be assigned to the correct inserts in each case 1 Standard centre plates and Standard automatic switches do not...

Page 49: ...B Management system Installation buttons as satellite unit can be maintained without change 2 wire Lighting Management satellite units attachment and insert can be maintained without change 3 wire Lig...

Page 50: ...ms 98 4 4 AUTOMATIC LIGHT 100 4 4 1 Components 101 4 4 2 Operating modes and functions 102 Observer operating mode 102 Presence detection operating mode 102 Continuous On function 103 Continuous Off f...

Page 51: ...LB MANAGEMENT LIGHT 51...

Page 52: ...E Electronic switch insert 1 channel 1704 ESE 2 wire satellite unit 1720 NE 3 wire satellite unit 1723 NE Universal LED dimmer for rail mounting UD 1755 REG LED power booster for rail mounting ULZ 175...

Page 53: ...ts is possible Delay times can be adjusted when using the Standard centre plate Satellite unit input for 2 3 wire satellite unit Suitable for switching the following loads per channel 2 300 W AGL 2 30...

Page 54: ...n of satellite units is possible Delay times can be adjusted when using the Standard centre plate Satellite unit input for 2 3 wire satellite unit Suitable for switching the following loads per channe...

Page 55: ...units is possible Electronic short circuit protection with permanent switch off after 7 seconds at the latest Electronic overtemperature protection The device uses the leading edge phase control or tr...

Page 56: ...he functions Installation or retrofitting of motion detectors in the stairwell Simple retrofitting of existing 3 wire or 4 wire installations Operation with the 1208 REG stairwell timers for rail moun...

Page 57: ...t the dimmer The standard touch dimmer can be installed in a commercially available device socket e g Kaiser 1055 02 according to DIN 49073 Overview of the functions LED dimmer with 2 wire 3 wire dete...

Page 58: ...l touch dimmer can be installed in a commercially available device socket e g Kaiser 1055 02 according to DIN 49073 Overview of the functions LED dimmer with 2 wire 3 wire detection automatic N connec...

Page 59: ...lled in a commercially available device socket e g Kaiser 1055 02 according to DIN 49073 Overview of the functions LED dimmer with 2 wire 3 wire detection automatic N connection detection 20 210 W mix...

Page 60: ...he functions Operation with mains power active operation The device provides the necessary control current in active operation for 18 DALI nodes Increase of the number of nodes to 72 DALI nodes using...

Page 61: ...lly The set operating mode is indicated by an LED Switching on is performed using a soft start that is gentle on the lamp Switching on with the last set brightness or with the saved switch on brightne...

Page 62: ...ng mode is indicated by an LED Switching on is performed using a soft start that is gentle on the lamp Switching on with the last set brightness or with the saved switch on brightness Switch on and mi...

Page 63: ...ming principle for the load is set automatically or manually Switching on with the last set brightness or with the saved switch on brightness Switch on and minimum brightness can be saved permanently...

Page 64: ...med using a soft start that is gentle on the lamp Switching on with the last set brightness or with the saved switch on brightness Switch on and minimum brightness can be saved permanently Electronic...

Page 65: ...ellite unit is mounted in device sockets according to DIN 49073 with an appropriate cover Overview of the functions Operation is identical to that of the universal rotary dimmer A maximum of ten 3 wir...

Page 66: ...des you with many different functions independently of the insert and attachment at the master unit In total the satellite unit has exactly as many functions as those of the attachment placed on the m...

Page 67: ...propriate dimming principle for the load is set manually or automatically LED indicates the selected operating mode Switching on is performed using a soft start that is gentle on the lamp Switching on...

Page 68: ...ctions Multiple dimmer power boosters for rail mounting can be connected to a dimmer Total power of the connected loads is distributed on dimmers and power boosters Connected loads are supplied using...

Page 69: ...t ic switch has a large detection area Overview of the functions Automatic switching of lighting depending on the heat of moving objects and ambient brightness Detection range 180 Extended detection r...

Page 70: ...ded installation height of 2 20 metres e g installed above a door it switches on the lighting during the first step of a person through the door Overview of the functions Automatic switching of lighti...

Page 71: ...rview of the functions Automatic switching of lighting depending on the heat of moving objects and ambient brightness Detection range 180 Extended detection range using satellite units Settings using...

Page 72: ...can make the settings conveniently using your smart phone and the Clever Config app Overview of the functions Automatic switching of lighting depending on the heat of moving objects and ambient brigh...

Page 73: ...e and the Clever Config app Overview of the functions Automatic switching of lighting depending on brightness and movement 360 Detection range for installation heights up to 6 metres Thee PIR sensors...

Page 74: ...ttachment for the 2 3 wire satellite unit Standard 2 gang centre plate The Standard 2 gang centre plate is a 2 channel attachment for 2 channel inserts It can be actuated at the top bottom and also fu...

Page 75: ...atus display and as pilot light It can be actuated at the top bottom and also full surface Overview of the functions Lighting control using appropriate inserts Automatic shading control using appropri...

Page 76: ...ies can be selected Morning evening offset setting Quick save Takeover of the current time as switching time Automatic setting of summer or winter time that can be disabled by the user Backlit segment...

Page 77: ...unit With sun protection and twilight function linked to brightness temperature sensor 40 switching times that are set for every day with an individual brightness value 0 100 percent blind height of t...

Page 78: ...at are repeated every 24 hours only applies to the eNet Radio centre plate and not to the eNet Standard Radio centre plate Locking function only applies to the eNet Radio centre plate and not to the e...

Page 79: ...tection and wind alarm Maximum brightness minimum brightness Dimming speed switch on switch off delay Up down dimming ramp Switch off prewarning continuous ON continuous OFF Hotel function delay time...

Page 80: ...ts are not suitable for safety critical applications 4 2 1 Components INSERTS REFERENCE NUMBER Relay switch insert 1 channel 1701 SE Relay switch insert 2 channel 1702 SE Electronic switch insert 1 ch...

Page 81: ...he 1 channel relay and electronic 1 channel switch inserts operate as switches This means they switch on the lighting for the first actuation and off again for the subsequent actuation A delay time ca...

Page 82: ...an installation button and an appropriate attachment An LB master unit can be controlled by LB satellite units by the LB satellite unit when it is activated putting a signal on terminal 1 of the inse...

Page 83: ...seconds The save process was success ful if the LED extinguishes ELECTRONIC SWITCH INSERT Connecting and installing insert L 1 N L 1 L 1 N 16 A N AC 230 V L Master unit 2 wire satellite unit Lighting...

Page 84: ...V halogen lamps leading edge phase control dimmable HV LED or compact fluorescent lamps leading edge phase control dimmable electronic transformers for halogen or LED lamps Proceed as follows to set t...

Page 85: ...matic switch are mounted on the pulse inserts A switch on signal is sent to the stairwell timers either via the manual operation of the centre plate or due to detection of movement The stairwell light...

Page 86: ...713 DSTE Mini universal dimmer LED 1724 DN Universal dimmer LED built in 1724 DEB Standard rotary dimmer LED 1730 DD Universal rotary dimmer LED 1731 DD Universal LED dimmer for rail mounting UD 1755...

Page 87: ...owing for the installation For the operation of multiple dimmers or power boosters in one sub distribution maintain a clearance of 1 TE approx 18 millimetres between the rail mountings to prevent any...

Page 88: ...edge phase control dimmable HV LED or compact fluorescent lamps leading edge phase control dimmable electronic transformers for halogen or LED lamps Proceed as follows to set the operating mode 1 Ens...

Page 89: ...e transformer manufacturers LED LAMPS Last but not least due to the EU wide ban of incandescent lamps in the framework of the Energy Saving Ordinance LED lamps have spread rapidly in recent years The...

Page 90: ...nuously adjusted using the delay time 10 20 30 40 ta ta ta ta t ms mains load U I The leading edge phase control principle is suitable for ohmic and inductive loads incandescent lamps or low voltage h...

Page 91: ...he occurring heat must be reliably dissipated to prevent damage The heat is usually dissipated into the wall via the support plate If this is not possible because the dimmer is installed for example i...

Page 92: ...combination Reduction of the rated load by 10 percent or 20 percent The two outer 500 W dimmers may only be loaded with 90 percent of the specified rated power i e with 450 W The inner 500 W dimmer m...

Page 93: ...RSAL DIMMER LED 1724 DM LED lights green Automatic calibration to the load Trailing edge phase control for incandescent lamps dimmable HV LED or compact fluores cent lamps as well as dimmable electron...

Page 94: ...t brightness again and becomes brighter slowly Save settings Briefly press button once LED lights in the colour of the selected operating mode LED lights LED flashes Light switches to the lowest brigh...

Page 95: ...ivity of the human eye Selection between linear and logarithmic dimming behaviour Switching process is relocated to the electronic ballast EVG no more wear in the relay no dimensioning of switching cu...

Page 96: ...electronic ballast Control centre electronic ballast electronic ballast electronic ballast electronic ballast Room 1 Room 2 Control centre electronic ballast electronic ballast electronic ballast ele...

Page 97: ...SETTING OPERATING MODE Leave the operating mode set to Universal initially and test the installation In the event of problems Set and check LED trailing edge phase control operating mode In the event...

Page 98: ...operating mode also reduce connected load if necessary Set operating mode manually Replace lamps with those of a different type Dimmer is connected without neutral conductor Connect neutral conductor...

Page 99: ...control Check operation in the LED leading edge phase control setting also reduce connected load if necessary Replace lamps with those of a different type Short circuit protection has tripped Disconn...

Page 100: ...d the light switches off if the delay time is not restarted by movement again Presence detectors are movement detectors that are typically placed in rooms where people are present longer The presence...

Page 101: ...dimmer LED 1711 DE 2 gang touch dimmer Universal LED 1712 DE 3 wire satellite unit 1723 NE Power DALI push button controller TW 1713 DSTE Pulse insert 1708 IE ATTACHMENTS REFERENCE NUMBER Standard aut...

Page 102: ...is suppressed In combination with the dimming inserts you can regulate the lighting depending on move ment to an individually specified brightness In this combination the automatic switch contin uousl...

Page 103: ...d is switched off continuously for a time of 0 5 to 5 hours or until manual deactivation The function behaves in principle like the Continuous OFF function with the difference that the function is aut...

Page 104: ...tches the load into the flashing operation approx 1 second ON 1 second OFF for the specified delay time The status LED 2 red LED also signals the alarm tripping until the deactivation of the alarm fun...

Page 105: ...he Clever Config app The constant light regulation always switches on with the saved switch on value memory value and then regulates to the specified brightness setpoint Change brightness value tempor...

Page 106: ...s switched on during the calibration STANDARD AND UNIVERSAL AUTOMATIC SWITCHES In the case of nominal installation height of the movement detectors of 1 10 metres or 2 20 metres the following results...

Page 107: ...the 1 1 m Universal automatic switch you can also activate deactivate the individual sensors using the app Thus the detection range on the left and on the right can be restricted by 60 The detection...

Page 108: ...ating manual DELAY TIME Using the delay time you specify how long the lighting stays switched on after each detection The delay time of the standard automatic switch is set to two minutes The delay ti...

Page 109: ...function Operating mode Detection area settings PIRs Sensitivity settings PIRs Switch on brightness memory value Brightness threshold Delay time Dynamic delay time Walking test Pulse operation Switch...

Page 110: ...129 5 4 5 Connecting wind sensor 130 5 5 FUNCTIONALITY DEPENDING ON THE ATTACHMENT 5 6 BLIND TYPES Hazards when using blind control systems 132 Possible applications 132 Requirements for the shading...

Page 111: ...LB MANAGEMENT SHADING 111...

Page 112: ...diverse JUNG design they can be selected to fit in with the rest of the electrical installation 5 1 Equipment Overview BLIND INSERTS REFERENCE NUMBER Standard blinds insert 1730 JE Universal blinds i...

Page 113: ...of the functions Intelligent insert for operation with centre plate and timer from LB Management Data based bidirectional communication of attachments and inserts Test operation without attachment is...

Page 114: ...centre plate and timer from LB Management Data based bidirectional communication of attachments and inserts Test operation without attachment is possible Polarity reversal function of the motor output...

Page 115: ...all inserts The attachment consists of a divided rocker that looks like a 2 gang rocker A coloured LED is assigned to each rocker half that is used for the function display status display and as pilo...

Page 116: ...es can be selected Morning evening offset setting Quick save Takeover of the current time as switching time Automatic setting of summer or winter time that can be disabled by the user Backlit segment...

Page 117: ...rotection and twilight function linked to brightness temperature sensor 40 switching times that are set for every day with an individual brightness value 0 100 percent blind height of the slats for bl...

Page 118: ...alue in the range of 5 80 000 lux via Bluetooth to the Universal Timer Sends the current temperature value in the range of 5 55 C via Bluetooth to the Universal Timer Sun protection function enables a...

Page 119: ...t are repeated every 24 hours only applies to the eNet Radio centre plate and not to the eNet Standard Radio centre plate Locking function only applies to the eNet Radio centre plate and not to the eN...

Page 120: ...n and wind alarm Maximum brightness minimum brightness Dimming speed switch on switch off delay Up down dimming ramp Switch off prewarning continuous ON continuous OFF Hotel function delay time Fully...

Page 121: ...n of the motor If you keep the TEST button pressed for shorter than one second the blind moves in the direction of the bottom limit position If you keep the TEST button pressed for longer than one sec...

Page 122: ...rol of multiple motors Also note the maximum duration for being switched on often referred to as ED in technical texts It can happen due to frequent moving that the motors heat up too strongly so that...

Page 123: ...the lock function is deactivated again For example this prevents the shutters on the terrace door closing automatically while the resident of the house is still present in the garden ACTIVATING AND DE...

Page 124: ...ition is reached release buttons and 1 second 4 seconds desired ventilation position press UP button within 4 seconds The ventilation position is saved and the blind moves back to the upper end positi...

Page 125: ...Standard blinds insert with any attachment switches a shading sys tem as a self contained system If multiple motors are connected to a blind insert the maximum connected load of total 700 watts must...

Page 126: ...ovides the advantage that it can be cascaded in any way so that the blinds can be controlled flexibly individually per room per floor or per building also with more than three hierarchy levels Group c...

Page 127: ...ly The entire system can be globally protected against storms if a wind sensor is connected A group controller is installed on every floor and the respective master is centralised with a higher level...

Page 128: ...nt phase conductors e g L1 L2 Mechanical and electronic satellites can be connected to a satellite unit input Mechanical satellites are blind buttons or switches These are suitable for connection and...

Page 129: ...serts together with each other as follows for group control Note In doing so the blind inserts can also be present on different phase conductors LN N AC 230 V L1 M 1 2 LN LN N AC 230 V L2 M 1 2 Local...

Page 130: ...1 2 L 1 Connect the wind sensor to the satellite unit input 2 according to the above connection plan 2 If you want to use the wind alarm for all outdoor blinds of a building connect the wind sen sor...

Page 131: ...ime can be disabled Astro function with coor dinates input via location service via eNet Server Astro function for 18 countries Coordinates input via location service via eNet Server Random function R...

Page 132: ...ice roller shutters on display windows As roller doors at the entrances of larger halls such as warehouses or sales rooms and car workshops REQUIREMENTS FOR THE SHADING MANAGEMENT Roller shutters are...

Page 133: ...various types of blinds that have different requirements can be controlled with all attachments shutters and blinds that only move to the upper and lower limit positions and the ventilation position...

Page 134: ...n the lee 5 7 2 Wind sensor interface L N 1 2 I II Test LED Setting test Wind strength Anemometer setting JUNG Art No 132 U WS Wind sensor with converter The wind sensor interface is the control gear...

Page 135: ...agement the anemometer can be used across all phases as central wind alarm for all blinds of an installation LN N AC 230 V L M 1 2 LN LN M 1 2 LN 1 2 L LN N AC 230 V L M 1 2 LN LN M 1 2 1 2 1 2 N AC 2...

Page 136: ...ion function is deactivated at the factory You specify a threshold for the sun brightness using the Clever Config app The setting range of the threshold is 4 000 80 000 lux The blinds move down automa...

Page 137: ...asures the brightness and temperature values and sends the currently measured values to the Universal Timer Bluetooth Depending on the recorded actual values and the specified values the Universal Tim...

Page 138: ...ulated control 147 6 3 6 Valve adjustment 147 6 3 7 Temperature sensor 148 6 3 8 Behaviour after power failure 148 6 3 9 Factory settings 149 6 4 ACTIVATE FUNCTIONS 6 4 1 Activate automatic manual ope...

Page 139: ...TEMPERATURE CONTROL 139...

Page 140: ...n temperature control is technically very easy to implement Produced in the diverse JUNG design they can be selected to fit in with the rest of the electrical installation 6 1 Equipment Overview INSER...

Page 141: ...connected to the room thermo stat The room temperature insert is mounted in wall boxes accord ing to DIN 49073 Overview of the functions Control of electric underfloor heating systems Control of elect...

Page 142: ...of satellite units is possible Shut off delays can be adjusted when using the Standard centre plate Satellite unit input for 2 3 wire satellite unit Suitable for switching the following loads per cha...

Page 143: ...ction of satellite units is possible Electronic short circuit protection with permanent switch off after 7 seconds at the latest Electronic overtemperature protection The device uses the leading edge...

Page 144: ...time Automatic setting of summer or winter time that can be disabled by the user Illuminated segment display enables reliable reading at dark installation locations Operating lock Heating optimisatio...

Page 145: ...is connected to C and the connector for heating is connected to heating The external sensors for external temperature measurement are connected to the two external sensor connections 6 2 1 Connecting...

Page 146: ...ten also enable rooms to be cooled The room thermo stat attachment supports this function with the heating or cooling operating mode In this operating mode continuous regulation to the specified cooli...

Page 147: ...CONTROL With two point control the output remains switched on until the specified setpoint tempera ture is exceeded by approx 0 5 C The output is not switched on again until the setpoint is undercut...

Page 148: ...sensor and the floor temperature by the external sensor to monitor the floor temperature If the maximum floor temperature is exceeded the underfloor heating is switched off until the floor temperatur...

Page 149: ...Cooling temperature 24 C Internal temperature sensor for the room temperature measurement is active Switch off of the display after 2 minutes without pressing any button is active Press and hold the R...

Page 150: ...The following menu items can be selected in the programming menu LOCK Activate or deactivate operating lock T1 T2 T3 Three memory areas for comfort and ECO temperature for the weekday blocks Mon Fri a...

Page 151: ...lected all times in the selected memory area are deactivated 4 Tap the Plus or Minus button to select the desired indicator 5 Tap the OK button to confirm the selection The first switching time for th...

Page 152: ...ap the Plus or Minus button to change the setpoint value 5 Tap the OK button to confirm your input In the same way you also set the values for the ECO temperature and if parametrised the cooling tempe...

Page 153: ...s to change the display 1 Tap and hold the OK and Auto buttons for longer than 10 seconds A countdown runs in the display If the countdown has reached 0 the actual temperature is shown on the display...

Page 154: ...MENTS 161 7 4 PAIRING THE DEVICES 162 7 4 1 Requirements for the pairing 162 7 4 2 Performing pairing 162 7 5 THE COMMISSIONING OF A DEVICE 164 7 5 1 Add device information 164 7 5 2 Making settings 1...

Page 155: ...THE CLEVER CONFIG APP 155...

Page 156: ...tion of the device The app also makes the commissioning of devices significantly easier as device configurations can be created easily transferred from device to device and imported from other install...

Page 157: ...ch on or off with a simple tap on the symbol or the button In combination with a dimming insert the dimming functions are also available using the Clever Config app Set the lighting brightness to the...

Page 158: ...ble slats there is also a controller available for adjusting the slats The app of course also has simple buttons for moving the shading up and down If the blind is defined in the configuration as roll...

Page 159: ...ing to the desired brightness using the rotary controller Alternatively you can change the numeric value using the and buttons Using the Change button you have access to further functions depending on...

Page 160: ...uetooth devices of the LB Management system can be sorted by room man aged and operated in the device list You add new devices using the symbol at the top right see chapter 7 4 Pairing the devices on...

Page 161: ...d devices are always only a fingertip away 7 2 Downloading the app The Clever Config App can be downloaded from the iTunes App Store iOS or Google Play Store Android 7 3 Installation requirements Prer...

Page 162: ...es is restricted for security reasons The app is installed and started 7 4 2 Performing pairing Proceed as follows to pair a device with the app 1 Call up the device list in the app 2 Tap on the symbo...

Page 163: ...after successful pairing The blue LED on the device lights for the confirmation of an active connection Note A maximum of eight mobile devices can be paired with one device When pairing the ninth dev...

Page 164: ...signed later for example ceil ing lamp 3 Protect the configuration if required by allocation of a password If Protect Configuration is activated the password must be entered before the pairing with ot...

Page 165: ...ings under the Parameters menu item TIME CONTROL In combination with the Universal Timer attachment you can create automatically running time programs under the Time Control menu item that switch the...

Page 166: ...see chapter 8 5 Astro function on page 190 You also set in the device configuration in the Sun Position menu that the app may access the local position You can take this over if you have already crea...

Page 167: ...arameters menu If required the parameter settings of devices created by you can also be simply adopted here Details about the adjustable parameters can be found in the chapters 4 LB Management Light o...

Page 168: ...tically using the geodata of the smart phone Astro time shift can be set for each switching time Automatic daylight saving time adjustment Automatic date and time update during connection with smart p...

Page 169: ...us On functions Activation and adjustment of the 0 5 5 hours ON or OFF function Activation of short time operation Activation and adjustment of the hotel function Activation and adjustment of the nigh...

Page 170: ...000 lux Temperature threshold Sun protection Off 5 50 C Twilight value 5 4 000 lux Dimming inserts Maximum brightness 75 100 percent Minimum brightness Basic brightness 1 40 percent Switch on brightn...

Page 171: ...ore than 4 minutes The twilight function is deactivated if the brightness exceeds the specified twilight value for longer than 4 minutes Note A brightness temperature sensor is necessary for this func...

Page 172: ...le devices 184 8 2 5 eNet Standard Radio centre plate 185 eNet Standard Radio centre plate 185 eNet Radio Centre Plate 186 8 3 OPERATION USING THE SATELLITE UNITS 187 8 3 1 Installation button as sate...

Page 173: ...OPERATION 173...

Page 174: ...ands full In combination with a dimming insert the lighting can also be dimmed Pressing and holding the top half of the button dims the lighting brighter pressing and holding the bottom half of the bu...

Page 175: ...op and bottom simultaneously for longer than four seconds The light switches off briefly and immediately on again The switch on brightness is saved If a saved brightness is saved again the dimmer swit...

Page 176: ...ry mode and disables satellite unit operation However you can continue to operate the left button half when the lock function is activated Activate the memory function by pressing and holding this Pre...

Page 177: ...Tap and hold the Memory button and the desired function button On Off Brighter Darker Up Down simultaneously The current switching time is saved if the LED lights green Saving again overwrites the old...

Page 178: ...ou reach the menu in which you can select and program various functions such as the astro function or the lock function You confirm the settings with the OK button Using the Reset button you can undo...

Page 179: ...the OK button to confirm the activation The display shows LOCK Alternatively activate the lock function in the menu with the Lock selection deactivate the lock function Press the right arrow button b...

Page 180: ...ctions such as the astro function or the lock function You confirm the settings with the OK button Using the Reset button you can undo the adjustments and reset the changed functions to the factory se...

Page 181: ...ivate the lock function in the menu with the Lock selection deactivate the lock function Press the right arrow button briefly change the programming Press the Programming Settings Menu button Confirm...

Page 182: ...e Bluetooth connection The full operation is performed using the Clever Config app You can conveniently access the time programs and the configuration of the timer Both can be protected with a passwor...

Page 183: ...the Universal Timer Bluetooth you can program the settings for light brightness or the position of the blinds using the Clever Config app activate deactivate the lock function Press and hold the right...

Page 184: ...h devices is possible with the app so that an automatic connection between Bluetooth device and attachment is always established when a device is in the range of the attachment You end the pairing mod...

Page 185: ...bottom Pressing and holding the lock function deactivates all automatic functions memory mode and disables satellite unit operation However you can continue to operate the left button half when the l...

Page 186: ...Functions in combination with blind insert Positioning of blinds via scene recall Position for sun protection and twilight Running time and ventilation position of the blind can be stored Functions i...

Page 187: ...ighting brighter or darker and save the setting depending on where you press the button If you keep the button pressed at the bottom a dimming insert is switched on to the minimum brightness If the ma...

Page 188: ...r attachments detect immediately whether they are on a light or blind control insert and adjust themselves accordingly to timer switch or blind timer operation This happens com pletely automatically T...

Page 189: ...ching time pairs for switching and dimming inserts You can set and manage up to 40 switching times using the Clever Config app with the Universal Timer Bluetooth The switching times do not have to be...

Page 190: ...r outdoor lighting The outdoor lighting should light in the morning and evening in the time that the occupants leave the house or come home The outdoor lighting is switched on Monday to Friday in the...

Page 191: ...a Lighting ON 5 15 6 00 8 30 8 15 17 00 22 30 16 00 OUTDOOR LIGHTING TIMER PROGRAM IN COMBINATION WITH ASTRO FUNCTION OFF January December OFF ON at 06 00 Sunrise OFF at 06 00 at the earliest Sunset O...

Page 192: ...can also be activated during the presence simulation 8 7 Alarm function When the alarm function is activated the load is always only switched on for a short time for approx 1 second as soon as any mo...

Page 193: ...72 73 Device pairing 152 Dimming behaviour 93 Dimming characteristics 93 Dimming principle 91 96 Drive function 166 E Electronic switch insert 1 channel 45 Energy saving 103 Energy saving function 80...

Page 194: ...4 65 S Satellite unit input 53 54 138 Schedule 28 Security password 152 Shading function 132 Shading position 28 Shading system 27 Short circuit protection 55 61 62 63 64 67 96 97 139 Short time opera...

Page 195: ...re plate 27 29 39 45 48 52 172 178 181 Universal dimmer for rail mounting LED 40 45 Universal dimmer LED built in 45 52 62 Universal timer bluetooth 52 77 79 84 110 115 119 127 129 132 133 164 Univers...

Page 196: ...JUNG GROUP COM ALBRECHT JUNG GMBH CO KG P O Box 1320 58579 Schalksm hle Germany Phone 49 2355 806 553 Fax 49 2355 806 254 international jung de For sales contacts in your country see jung group com co...

Reviews: