LB management
eNet radio centre plate
Save switch-on brightness
■
Adjust the brightness.
■
Press the buttons (3a) and (3b) for longer than 4 seconds.
Switch-on brightness is saved. For confirmation, the light is switched off briefly and
switched on again.
Delete switch-on brightness
■
Press button (3) briefly: Light switches on at the saved switch-on brightness.
■
Press the buttons (3a) and (3b) for longer than 4 seconds.
The switch-on brightness has been deleted.
Switching on takes place at the last brightness value set. For confirmation, the light is
switched off briefly and switched on again.
7
Transmitter function of the attachment
In addition to operating its own insert, the attachment also sends radio telegrams to remote
eNet actuators. In this way, a comprehensive central control system can be implemented. Irre-
spective of local use, the attachment can be used for switching, dimming and operating Vene-
tian blinds of remote actuators.
Signalling of the status LED
As soon as the button (3a) or (3b) is pressed or released, the red status LED first signals radio
transmission.
–
The status LED lights up red for 3 seconds.
The actuator status/group status is then displayed (see Query group status).
Polling sum status
■
Press buttons (3a) and (3b) for 1 to 4 seconds.
If there is no status message from at least one remote actuator, a transmission error is
signaled. Status LED flashes red quickly for 5 seconds.
Signalling of the group status:
–
Status LED turns green for 3 seconds:
At least one actuator is switched on, or one Venetian blind is not in the top end position.
–
Status LED remains off:
All the actuators are switched off or the Venetian blinds are all in the upper end position.
8
Activate functions
Saving switching times - Memory operation
■
In addition to normal operation with the button (3a) or (3b), press the button (4b) for
longer than one second.
The insert switches and the switching time is saved.
The device switches to memory operation. The function LED (5) turns continuously green.
Saved switching operations are repeated in a 24-hour cycle.
An upward and downward movement time, or on and off time, can be saved. The old
switching time will be replaced if a new one is saved.
To delete all times, press button (4b) for longer than 20 seconds until the function LED (5)
lights up green for a second time.
After programming with the eNet Server or eNet SMART HOME app, the switching times
saved in memory operation have been deleted.
Activating / deactivating memory operation
■
Press the button (4b) for longer than 4 seconds.