background image

LB management 

eNet radio centre plate

Parameters

Setting options, Basic
setting

Explanations

Manual saving of
the scene values

On, Off 
Basic setting: On

Disables the saving of the current actuator state
(On/Off) as scene value in an actuator for a com-
mand via a transmitter.

Switch-off warn-
ing

On, Off 
Basic setting: Off

If the switch-off warning is active, the light is not
switched off directly. The light briefly goes off 30,
20 and 10 seconds before permanent switch-off.
During the switch-off warning, a switch-on com-
mand activates direct switch-on. It is not possible
to terminate the time using a switch-off com-
mand.

Priority, lock-out
protection

0...4 
Basic setting: 1

Specifies the priority for recalling and removing a
scene of type Lock-out protection for the channel.

Activate lock-out
protection switch-
ing state

On, Off 
Basic setting: Off

Defines the behaviour of the output on activating
the lock-out protection.

Deactivate lock-
out protection
switching state

On, Off 
Basic setting: Off

Defines the behaviour of the output on deactivat-
ing the lock-out protection. Only visible when the
priority for the lock-out protection is 0.

Priority, restraint

0...4 
Basic setting: 2

Specifies the priority for recalling and removing a
scene of type Restraint for the channel.

Activate forced
operation switch-
ing state

On, Off 
Basic setting: On

Defines the behaviour of the output on activating
the forced operation.

Deactivate forced
operation switch-
ing state

On, Off 
Basic setting: Off

Defines the behaviour of the output on deactivat-
ing the forced operation. Only visible when the
priority for the forced operation is 0.

Priority, wind
alarm

0...4 
Basic setting: 3

Specifies the priority for recalling and removing a
scene of type Wind alarm for the channel.

Activate wind
alarm switching
state

On, Off 
Basic setting: Off

Defines the behaviour of the output on activating
the wind alarm.

Deactivate wind
alarm switching
state

On, Off 
Basic setting: Off

Defines the behaviour of the output on deactivat-
ing the wind alarm. Only visible when the priority
for the wind alarm is 0.

Priority, sun pro-
tection

0...4 
Basic setting: 0

Specifies the priority for recalling and removing a
scene of type Sun protection for the channel.

Activate sun pro-
tection switching
state

On, Off 
Basic setting: On

Defines the behaviour of the output on deactivat-
ing the sun protection. Only visible when the pri-
ority for the sun protection is 0.

Deactivate sun
protection switch-
ing state

On, Off 
Basic setting: Off

Defines the behaviour of the output on deactivat-
ing the sun protection. Only visible when the pri-
ority for the sun protection is 0.

Priority, twilight

0...4 
Basic setting: 0

Specifies the priority for recalling and removing a
scene of type Twilight for the channel.

Activate twilight
switching state

On, Off 
Basic setting: On

Defines the behaviour of the output on activating
the twilight function.

13 / 29

32597903

07.08.2019

J0082597903

Summary of Contents for FM 1701 Series

Page 1: ...tion takes place via a non exclusively available transmission path and is therefore not suitable for safety related applications such as emergency stop and emergency call These instructions are an int...

Page 2: ...ventilation position of the blind shutter can be saved Functions in combination with light insert Scene operation possible Switch on brightness can be saved permanently when combined with flush mount...

Page 3: ...press button 3b within the next 4 seconds The running time is saved The blind shutter moves back to the upper end position The change over time of the slats for the venetian blind and time fabric str...

Page 4: ...y group status Polling sum status Press buttons 3a and 3b for 1 to 4 seconds If there is no status message from at least one remote actuator a transmission error is signaled Status LED flashes red qui...

Page 5: ...sconnected and parameters are reset to the default setting The connections in the radio transmitters and radio actuators are preserved and must be deleted separately Load is switched off Press buttons...

Page 6: ...ccessful All the memory locations in the attachment or radio transmitter are occupied Connecting attachment to radio actuator Up to 10 radio actuators can be connected to a transmitter in a single ste...

Page 7: ...s a channel button Unused The channel is not displayed in the eNet SMART HOME app and is disabled for use in the com missioning interface Actuator channel function Switch insert Dimming insert Extensi...

Page 8: ...ace Operating mode Dimming Normal operation Continuous on Continuous off Basic setting Normal operation Normal operation The insert can be operated with radio transmit ters via an extension or directl...

Page 9: ...or use in the com missioning interface Venetian blind operating mode Roller shutter Venetian blind Awning Basic setting Roller shutter Roller shutter A shutter is controlled The channel is integrated...

Page 10: ...ion in the eNet SMART HOME app The fan channel switches on and off with a delay depending on the set parameters Switching fan The switching channel is not integrated in any central function The fan ch...

Page 11: ...delay Repeated switch off commands restart the delay time If the load has not yet been switched off due to the delay when a switch on command comes then the load will remain on In Flashing operating...

Page 12: ...o grammed to apply the change Extended channel settings switching Parameters Setting options Basic setting Explanations Operating mode Switching operation Push button operation Flashing Continuous on...

Page 13: ...our of the output on activating the forced operation Deactivate forced operation switch ing state On Off Basic setting Off Defines the behaviour of the output on deactivat ing the forced operation Onl...

Page 14: ...brightness Note If parameters or scene values are set to a level lower than the minimum brightness then the sys tem will dim to minimum brightness Maximum bright ness 75 100 Basic setting 100 Specifie...

Page 15: ...ured 0 s in addition to motion detector commands all switching or dimming commands also lead to switching on for the duration of the run on time If no run on time is configured 0 s all switch ing or d...

Page 16: ...100 Basic setting 100 Brightness value set by the output after voltage return mains voltage The parameter Beha viour after voltage return must be set to Con figured brightness Note If the value is abo...

Page 17: ...ting 0 Defines the behaviour of the output on activating the wind alarm Deactivate wind alarm brightness value 0 100 Basic setting 0 Defines the behaviour of the output on deactivat ing the wind alarm...

Page 18: ...e delay when a switch on command comes then the load will remain on Extended channel settings 3 wire extension Parameters Setting options Basic setting Explanations Operating mode Normal operation Con...

Page 19: ...essential if scene or position movements are to occur Slat change over time fabric stretching time 0 ms 10 sec 300 ms 10 s Basic setting 0 ms 300 ms Absolute time for changing over Venetian blind sla...

Page 20: ...Basic setting 0 Defines the behaviour of the output on deactivat ing the lock out protection Only visible when the priority for the lock out protection is 0 Deacitvate lock out protection slat positio...

Page 21: ...tection slat posi tion 0 100 Basic setting 100 Defines the slat position of the output on activat ing the sun protection Only visible when the Venetian blind operating mode is set Deactivate sun prot...

Page 22: ...n time entered here If no run on time is entered here the default run on time of 2 minutes is applied Use run on time On Off Basic setting Off On If a run on time is configured 0 s in addition to moti...

Page 23: ...ttings Switching fan Parameters Setting options Basic setting Explanations Operating mode Switching operation Push button operation Flashing Continuous on Continuous off Basic setting Switching operat...

Page 24: ...riority wind alarm 0 4 Basic setting 3 Specifies the priority for recalling and removing a scene of type Wind alarm for the channel Activate wind alarm switching state On Off Basic setting Off Defines...

Page 25: ...etting 0 s If a run on time is entered and the Use run on time parameter is activated the actuator no longer remains permanently switched on but only for the duration of the run on time entered here o...

Page 26: ...n using the button Behaviour on voltage return On Off Last value Basic setting Off Defines the behaviour of the output after voltage return Timer behaviour voltage return Off Restart Basic setting Off...

Page 27: ...o tection 0 4 Basic setting 0 Specifies the priority for recalling and removing a scene of type Sun protection for the channel Activate sun pro tection switching state On Off Basic setting On Defines...

Page 28: ...the attachment Operating hours Display of the operating hours since the last restart in the Settings window Venetian blind Display value Explanations Position value venetian blind The position value...

Page 29: ...m type art no FM 1701 meets the directive 2014 53 EU You can find the full article number on the device The com plete text of the EU Declaration of Conformity is available under the Internet address w...

Reviews: