25
7 Parameter overview
7.2
Configuration data
The configuration is stored in the parameter manager and is transferred via the IO-Link interface in an
acyclic process.
General
Designation
Index Sub in-
dex
Data type Value range
Default Ac-
cess
right
a
a
RW = Read and write access
RO = Read-only access
WO = Write-only access
Description
Data format
64
0
TENUM
(1 byte)
0 = Floating point
1 = Integer
Float-
ing
point
RW
Temperature pro-
cess value unit
120
0
TENUM
(1 byte)
0 = °C
1 = °F
°C
RW
Temperature pro-
cess value offset
121
0
TFLOAT
-999 to 999
0
RW
Temperature fil-
ter time constant
122
0
TFLOAT
0 to 100 s
0
RW
Standard com-
mand
2
0
Button
130 = Reset to de-
fault setting
-
WO
The default
data is loaded.