24
7 Parameter overview
7
Parameter overview
7.1
Process data
The data is transferred in a cycle via the IO-Link interface to the IO-Link master (PDI = Process Data
Input). The entire process data can be extracted via index 40 and subindex 0.
Designation
Data type Value range
Default
Description
Temperature pro-
cess value
TFLOAT
or
TINT32
0
The "Data format" configuration
parameter can be used to switch
between the data type TFLOAT
and TINT32.
Temperature pro-
cess value unit
TUINT8
0 = °C
1 = °F
°C
Temperature pro-
cess value status
TUINT8
(bit field)
Bit 0 = Process value in-
valid (overrange or un-
derrange)
Bit 1 = Error in configu-
ration data
Bit 2 = Error in calibra-
tion data (device is de-
fective)
0
In order to provide a simple way to
identify errors, alongside IO-Link's
standard troubleshooting func-
tions, a status byte is included in
the process data. This signals er-
rors in the sensor and is easy to
analyze in the higher-level sys-
tem. Errors are entered on a bit by
bit basis but can also be combined
to contain several device errors.
Switching output
TUINT8
(bit field)
Bit 0 = Switching
output 1
Bit 1 = Switching
output 2
0
0 = Not switched
1 = Switched
Summary of Contents for 00725428