FX-3R Maintenance
Guide
5-8
Rev. 1.00
XL
specification
Figure 5-5-3-5 Sensor Amplifier with XL Specification
<Setting procedure>
1) Change the SET/RUN change-over switch
g
to the “SET”
mode.
2) Press the operation key
i
to display the operation mode
setup indication (indication is “0-op”). Press the triangle
button
i
to set the dark ON (don).
3) Press the operation key
i
to display the detection function
mode setup indication (1-Fn). Press the triangle button
i
to
set the standard mode (Stnd).
4) Press the square button of the operation key
i
to display
the threshold value teaching level setup indication (3-tL)
and press the triangle button
i
to set “40P”.
5) Press the square button of the operation key
i
to display
the MODE key setup indication (5-Md). Press the triangle
button
i
to set the power tuning run mode (PtUn).
6) Press the square button of the operation key
i
to display
the power tuning target value setup indication (PL). Press
the triangle button
i
to set “100”.
7) Press the yellow button of the operation key
i
to display
the external input setup indication (A-rM). Press the triangle
button
i
to set the teaching without transmission
workpiece (thrU).
c
RUN indicator 1 CH (Orange)
d
Main digital display (Red)
e
RUN indicator 2 CH
(Orange)
f
Sub-digital display (Green)
i
Operation key
h
Channel change-over switch
g
SET/RUN change-over switch
j
Lock lever
Change to the
SET mode.
Figure 5-5-3-6 SET Mode
Figure 5-5-3-7 Operation Mode
Figure 5-5-3-8 Detection
Function Mode
Figure 5-5-3-9 Threshold Value
Teaching Level
Figure 5-5-3-10 MODE Key
Setup
Figure 5-5-3-11 Power Tuning
Target Value
Figure 5-5-3-12 External Input
Setup